20
Module specifications
Dual/quad electrical
Dual/quad electrical channel
modules
N1045A
1
N1055A
1
Channel options
(number of channels; F = female; M = male)
02F/02M 04F/04M 32F/32M 34F/34M 52F/52M 54F/54M
Number of channels
2
2 4 2 4 2 4
Electrical channel bandwidth 20/35/45/60 GHz 35 GHz
4
35 GHz
4
35/50 GHz 35/50 GHz
Transition time
(10% to 90% calculated from TR = 0.35/
BW)
17.5/10/7.8/5.8 ps 10 ps 10 /7 ps
Channel-to-channel skew range ± 100 ps ± 100 ps
RMS noise
Characteristic 275/425/500/750 µV 550 uV 550 / 950 uV
Maximum 950 µV (60 GHz) 650 uV 980 uV
Scale factor (per division)
Minimum 1 mV/division 1 mV/division
Maximum 100 mV/division 100 mV/division
DC accuracy (single marker) ±0.4% of full scale
±2 mV ±4% of (reading-
channel offset), (60 GHz)
±0.4% of full scale
±2 mV ±4% of (reading-channel offset), (50 GHz)
DC offset range
(referenced from center of screen)
±500 mV ±500 mV
Input dynamic range
(relative to channel offset)
±400 mV ±400 mV
Maximum input signal ±2 V (+16 dBm) +2 V / -1 V
Nominal impedance 50 Ω 50 Ω
Reflections
(for 30 ps rise time)
20% 20%
Electrical input
3
1.85 mm (female or male
option)
2.92 mm
(female or male option)
1.85 mm
(female or male option)
1. Module is supported by 86100D DCA-X mainframe and later.
2. Upgradable from 2 channel to 4 channel after purchase (return to Agilent).
3. Connector style is the same on all channels and is selected at time of order.