Agilent Technologies 4352B Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Multimètres Agilent Technologies 4352B. Agilent 4352S VCO/PLL Signal Test System Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Agilent
4352S VCO/PLL Signal Test System
A Customized, Multi-Functional Test System
for VCO/PLL Evaluation Up to 12.6 GHz
Product Overview
Essential for characterization of synthesized oscillator design
and for VCO production test in high-throughput applications
Discontinued Product Information
— For Support Reference Only —
Information herein, may refer to products/services no longer supported.
We regret any inconvenience caused by obsolete information. For the
latest information on Agilent’s test and measurement products go to:
www.agilent.com/find/products
In the US, call Agilent Technologies at 1-800-829-4444
(any weekday between 8am–5pm in any U.S. time zone)
World-wide Agilent sales office contact information is available at:
www.agilent.com/find/contactus
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Product Overview

Agilent4352S VCO/PLL Signal Test SystemA Customized, Multi-Functional Test System for VCO/PLL Evaluation Up to 12.6 GHzProduct OverviewEssential for c

Page 2 - Sources characteristics

Limit line functionTo design for the optimized characteristics of the device, circuitadjustments are often required. The4352S’s limit line function en

Page 3 - Product Summary

Source characteristicsDc power supplyDc voltage level :• 0 to +15.5 V (50 mA max.)Dc voltage resolution:•1 mVDc voltage accuracy:• ±(0.2 % + 2 mV)Nois

Page 4 - Outstanding phase noise

Frequency transientFrequency range:• 100 MHz to 3 GHz measurement range(frequency span)• 2 MHz, 20 MHz, MAX (see table 1)Frequency resolution:• Measur

Page 5 - 24-bit I/O interface

13RF-in port:Connector: N(f)Frequency: 10 MHz to 12.6 GHzRF power (heterodyne path):Input VSWR: < 1.5Frequency: 2.4 GHz to 12.6 GHzLevel:@ ATT =

Page 6 - 43521A downconverter unit

Guideline of signal generatorselectionThe recommended signal generatorsAgilent 8664A with Option 004 (enhanced spectral purity)Frequency: 100 kHz to

Page 7

Agilent 43521A downconverter unitFurnished accessories:• N-N cable (18 cm), 2 ea. (P/N 8120-4387)• N-N cable (50 cm), 1 ea. (P/N 43521-61638)• BNC-BNC

Page 8 - Spectrum monitoring

MS-DOS® is a U.S. registered trademark ofMicrosoft Corp.www.agilent.com/find/emailupdatesGet the latest information on the products andapplications yo

Page 9 - Marker analysis function

Agilent 4352S Key SpecificationsSources characteristicsDC power voltage:• 0 to 15.5 V (50 mA max.)• 1 mV stepDC control voltage:• 0 to 20 V (20 mA max

Page 10 - Limit line function

Synthesized local oscillators (LOs)for frequency conversion existeverywhere that communicationsand wireless radios live. The synthesized oscillator (s

Page 11 - Measurement parameters

Outstanding phase noise measurement capabilityThe 4352S system’s innovative “carrier lock multi-mode PLL” technology provides accurate and high-speed

Page 12 - Operating conditions

Controlling the output frequency offree-running VCOs by your 4352SUsing the 4352S, you can control the output frequency of free-runningVCOs very easil

Page 13 - LO-in port:

43521A downconverter unitWith growth in wireless technologiestoward more efficient designs athigher frequencies, the 4352S including the 43521A downco

Page 14 - Ordering Information

The “Analyzer” mode simplifies the complete characterization ofVCO/PLL performance and makesquality oscillator design easy. Thedisplays present the pa

Page 15 - Evaluated Above12.6 GHz

Spectrum monitoringThe 4352S can make a spectrummeasurement with up to 10 MHzspan. This allows you to easilydetect unfavorable signals such asharmonic

Page 16 - Agilent Direct

Integrated noise functionIn phase noise evaluation, the latestfirmware can make not only the logsweep but also linear sweep. Whenthe integrated noise

Commentaires sur ces manuels

Pas de commentaire