The TERM CODE variable is made up of DEVSEL#, TRDY#, and
STOP#. The following lists the bit pattern and the corresponding symbol.
Symbol DEVSEL# TRDY# STOP#
MASTER ABORT 1 1 1
SPLIT RESPONSE 1 0 1
TARGET ABORT 1 1 0
SINGLE DATA DISC 1 0 0
RETRY 0 1 0
DISC NXT ADB 0 0 0
The hardware layout of the FS2010 made it impossible for the signals to
be connected to the logic analyzer in a logical order. Therefore, bit re-
ordering is done in the configuration file to make the data easier to view.
The bit re-ordering function can be found in the FORMAT menu.
Below is a list of labels that have been re-ordered
ADDR
ADDR_B
STAT
AD_HI
AD_LO
C/B3_0
CYCLE
TERM CODE
Bit Re-ordering