4 Making Measurements
92 Agilent 3000 Series Oscilloscopes User’s Guide
Vrms (Root-Mean-Square Voltage)
The true root- mean- square voltage over the entire waveform.
Where:
x
i
= value at i
th
point.
n = number of points.
Overshoot
Defined as (Vmax-Vtop)/Vamp, useful for square and pulse waveforms. See
Figure 40 on page 90.
Preshoot
Defined as (Vmin-Vbase)/Vamp, useful for square and pulse waveforms.
See Figure 40 on page 90.
RMS
x
i
2
i 1=
n
n
----------------=
Vue de la page 91