Chapter 1 173
GPIB Command Dictionary
CONFigure subsystem
:SPOR9|SPORT9|SB9|SP9:MODem:CONFigure:ECEQivalent?
This command reports the decimal equivalent of the escape character
entered with the CONF:SPOR9:MOD:CONF:ECH.
Syntax
CONF:SPOR9:MOD:CONF:ECEQ?
Screen/field equivalent
CONF:SPOR9:MOD:CONF:ECEQ? queries the Decimal Equivalent
field on the MODEM CONFIGURE screen when the Serial Port field
is set to Port 9.
:SPOR9|SPORT9|SB9|SP9:MODem:SECurity:STATe
:SPOR9|SPORT9|SB9|SP9:MODem:SECurity:STATe?
This command controls the usage of a password security challenge.
‘Off’ - no password challenge on connection
‘On’ - issues a password challenge on connection. The caller must
enter a password. The password must match the string entered in
the CONF:SPOR9:MOD:SEC:PASS command.
Syntax
CONF:SPOR9:MOD:SEC:STAT ‘On’
‘Off’
CONF:SPOR9:MOD:CONF:STAT?
Screen/field equivalent
CONF:SPOR9:MOD:SEC:STAT controls the Incoming Call Security
field on the MODEM CONFIGURE screen when the Serial Port field
is set to Port 9.