Vue de la page 0
Optical Component Test
sA
s
Enabling Broadband Infrastructure
Photonic testing of next generation
low cost optical devices
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - Optical Component Test

Optical Component TestsAsEnabling Broadband InfrastructurePhotonic testing of next generationlow cost optical devices

Page 2 - Agilent Technologies

www.agilent.com/comms/lightwaveApplicationsAgilent 8166B Lightwave Multichannel System•Extender platform to flexibly adjust high channel-count applica

Page 3

www.agilent.com/comms/lightwaveSource ModulesAgilent 81600B Tunable Laser Modules•Complete wavelength coverage from 1260 nm to 1640 nm•Low SSE output

Page 4

www.agilent.com/comms/lightwaveSource ModulesAgilent 81600B Tunable Laser Modules (cont.)132/142 130/140/150/160 200Output Power, peak (typ) ≥+9/+8.5d

Page 5

www.agilent.com/comms/lightwaveSource ModulesAgilent 8198xA and 8194xA Compact Tunable Laser Source•Modular design for multichannel platform•110 nm co

Page 6

www.agilent.com/comms/lightwaveSource ModulesAgilent 8198xA and 8194xA Compact Tunable Laser Source (cont.)81980A and 81989A Compact Tunable Laser Sou

Page 7

www.agilent.com/comms/lightwaveSource ModulesAgilent 81662A and 81663A DFB Laser Modules•Center wavelengths from 1529 to 1610 nm•Fine tuning capabilit

Page 8

www.agilent.com/comms/lightwaveSource ModulesAgilent 81662A and 81663A DFB Laser Modules (cont.)SpecificationsSpecifications describe the instruments’

Page 9 - Lightwave Multimeter

www.agilent.com/comms/lightwaveResponse ModulesAgilent 8165xA Fabry-Perot Laser Modules•SMF with 1310nm, 1550nm or 1310/1550nm and MMF with 850nm•Sele

Page 10 - Applications

www.agilent.com/comms/lightwaveResponse ModulesAgilent 8165xA Fabry-Perot Laser Modules (cont.)High power modules, 13dBmAgilent 81655A Agilent 81656A

Page 11 - Source Modules

www.agilent.com/comms/lightwaveResponse ModulesAgilent 8163xA/B and 8162xB Optical Power Meter•Complete wavelength range, 750 nm – 1800 nm•Low uncerta

Page 12

www.agilent.com/comms/lightwaveAgilent TechnologiesIntroductionAAs the optical communication industry matures, the role played by measurement equipmen

Page 13

www.agilent.com/comms/lightwaveResponse ModulesAgilent 8163xA/B and 8162xB Optical Power Meter (cont.)Agilent 81635A Agilent 81634B Agilent 81630BSe

Page 14

www.agilent.com/comms/lightwaveResponse ModulesAgilent 8163xA/B and 8162xB Optical Power Meter (cont.)Agilent 81636B continuedReturn Loss >40 dBNo

Page 15

Agilent 81624B Agilent 81624B Agilent 81626B Agilent 81626BCalibration Option C01/C02 Calibration Option C01/C02Sensor Element InGaAs, ø 5 mm In

Page 16

www.agilent.com/comms/lightwaveResponse Modules Agilent 81610A and 81613A Return Loss Module81610A 81613ASource external input only Fabry-Perot Lase

Page 17 - Response Modules

www.agilent.com/comms/lightwaveSignal ConditioningAgilent 8157xA High-Power Optical Attenuators•Low insertion loss of 0.7 dB•Excellent Wavelength flat

Page 18

www.agilent.com/comms/lightwaveSignal ConditioningAgilent 8157xA High-Power Optical Attenuators (cont.)8157xA 81578A-050 81578A-062Connectivity Strai

Page 19

www.agilent.com/comms/lightwaveSignal ConditioningAgilent 8159xB Modular Optical Switches•Wide wavelength range for single mode and multi modeapplicat

Page 20

www.agilent.com/comms/lightwaveSignal ConditioningAgilent 8159xB Modular Optical Switches (cont.)Modular Optical Switch Specifications81591B 81594B 81

Page 21

www.agilent.com/comms/lightwaveSpectrum AnalysisAgilent 83453B High-Resolution Spectrometer•Characterization of a laser linewidth with 1 MHz (0.008 pm

Page 22

www.agilent.com/comms/lightwaveSpectrum AnalysisAgilent 83453B High-Resolution Spectrometer (cont.)Agilent Technologies warrants that the specificatio

Page 23

www.agilent.com/comms/lightwaveAgilent TechnologiesOptical Component TestAgilent’s broad range of optical test solutions for component and equipment m

Page 24 - Signal Conditioning

www.agilent.com/comms/lightwaveSpectrum AnalysisAgilent 86120B/C and 86122A Multi-Wavelength Meters•Characterize WDM spectra during R&D, manufactu

Page 25

www.agilent.com/comms/lightwaveSpectrum AnalysisAgilent 86120B/C and 86122A Multi-Wavelength Meters (cont.)SpecificationsThe technical specifications

Page 26

www.agilent.com/comms/lightwaveSystems & Polarization AnalysisAgilent 8169A Polarization Controllers•Precise manual and remote adjustments of pola

Page 27

www.agilent.com/comms/lightwaveSystems & Polarization AnalysisAgilent 86038B Photonic Dispersion and Loss Analyzer•Fastest measurement speed for h

Page 28 - Spectrum Analysis

www.agilent.com/comms/lightwaveSystems & Polarization AnalysisAgilent 86038B Photonic Dispersion and Loss Analyzer (preliminary)Group Delay and Di

Page 29

www.agilent.com/comms/lightwaveLightwave Component AnalyzerAgilent N4373A Lightwave Component Analyzer•Calibrated frequency-response measurements of f

Page 30

www.agilent.com/comms/lightwaveAccessoriesOptical Head AdaptersOptical Head AdapterThese adapters are to be used with Agilent optical heads only. The

Page 31

This page intentionally left blank.

Page 32

This page intentionally left blank.

Page 33 - Agilent 8169A Block Diagram

This page intentionally left blank.

Page 34

www.agilent.com/comms/lightwaveApplicationsOptical Component Test ApplicationsGigabit Ethernet and Fibre ChannelFiber optic technology is increasingly

Page 35 - Lightwave Component Analyzer

Agilent Technologies’ Test and Measurement Support, Services,and AssistanceAgilent Technologies aims to maximize the value you receive, whileminimizin

Page 36 - Optical Head Adapters

www.agilent.com/comms/lightwaveApplicationsOptical Component Test ApplicationsCoarse Wavelength Division MultiplexingImprovements in the bandwidth of

Page 37

www.agilent.com/comms/lightwaveApplicationsModular Test and Measurement Platform for Optical Networks and Components FlexibleModular instrumentation t

Page 38

www.agilent.com/comms/lightwaveApplicationsEnabling Service Innovation Manufacturing Integration Test Speed, Accuracy AutomationOptical Component Test

Page 39

www.agilent.com/comms/lightwaveApplicationsAgilent 8163B Lightwave MultimeterOptica8163B•Benchtop and smart carry-along instrument•Ready-to-use applic

Page 40

www.agilent.com/comms/lightwaveApplicationsAgilent 8164B Lightwave Measurement System& Photonics Test – Enabling Broadband InfrastructureLightwave