1-15
8753ES Specifications and Characteristics
Instrument Specifications
Table 1-13 Test Port Output
8753ES Test Port Output
Description Specification Supplemental Information
Signal Purity
a
2nd Harmonic 16 MHz to 1.5 GHz
(source freq.)
16 MHz to 3 GHz
(Option 006, source freq.)
at maximum output power < 25 dBc (Option 002 only) < 25 dBc, char.
(non-Option 002)
at 10 dB below maximum
output power
< 40 dBc, typ.
at 20 dB below maximum
output power
< 50 dBc, typ.
3rd Harmonic 16 MHz to 1 GHz
(source freq.)
16 MHz to 2 GHz
(Option 006, source freq.)
at maximum output power < 25 dBc (Option 002 only) < 25 dBc, char.
(non-Option 002)
at 10 dB below maximum
output power
< 40 dBc, typ.
at 20 dB below maximum
output power
< 50 dBc, typ.
Non-harmonic Spurious
Mixer Related
at maximum output power < 30 dBc, typ.
at 20 dB below maximum
output power
< 55 dBc, typ.