Page 1 - Firmware Upgrade Kit

HP/Agilent 8922 GSM Test SetFirmware Upgrade KitAgilent Part No. 08922-90236Printed in UKJuly 1999

Page 2

10HP/Agilent 8922S Firmware Upgrade Kit,08922-61149, Revision B.07.11Table 1-6 ROM Parts List for Agilent 08922-61149, HP/Agilent 8922SFirmware Upgrad

Page 3 - 1 HP/Agilent 8922 Upgrade Kit

11HP/Agilent 8922S Option 010 FirmwareUpgrade Kit, 08922-61184, Revision C.01.08Table 1-7 ROM Parts List for Agilent 08922-61184, HP/Agilent 8922S Opt

Page 4

12Clearing Non-Volatile MemoryNOTE It is important to Clear the HP/Agilent 8922 non-volatile RAM beforeand after the firmware upgrade.To clear non-vola

Page 5 - 08922-61087, Revision A.05.04

13Removal InstructionsStep 1. Remove the instrument’s top cover.1. Remove the top bumper mounting screws (4 places).2. Remove the side bumper mounting

Page 6 - 08922-61088, Revision A.04.02

14Figure 1-1 Location of A9 global test board and A33 Hop controllerNOTE If you are upgrading an HP/Agilent 8922F/H/S, go to step 5.Step 3. Replace A9

Page 7 - 08922-61116, Revision B.06.07

15Figure 1-2 Location and orientation of A9 U264. Check the orientation of the EPROM A9U26 matches the templateshown on the board.5. Re-install the A9

Page 8 - 08922-61089, Revision A.04.02

16Figure 1-4 Loosening the A8 memory board mounting screwsNOTE If your Memory Board is secured with two screws, remove the bottomcover for access (exp

Page 9 - 08922-61117, Revision B.06.07

17Figure 1-5 Removing the bottom cover2. Remove the A8 Memory board only.3. Replace ROMs supplied in the kit in accordance with the diagrambelow.Figur

Page 10 - 08922-61149, Revision B.07.11

18Figure 1-7 HP/Agilent 8922H/S Memory board IC replacement diagram4. Re-install the A8 Memory Board.NOTE Use the templates marked on the boards to co

Page 11

19Figure 1-8 ROM U15 to U18 replacement3. Re-install the A32 GSM Controller board.

Page 12 - Clearing Non-Volatile Memory

© Copyright 1999, Agilent Technologies. All rights reserved. Reproduction, adaptation, or translation without priorwritten permission is prohibited, e

Page 13 - Removal Instructions

20Completing the ROM upgradeUpon initial powerupWhen new ROMs are installed in the HP/Agilent 8922, and theinstrument is first powered on, there may be

Page 14

21Calibrating the Internal ReferenceTo complete the ROM upgrade, you must recalibrate the internalreference.NOTE Before recalibrating the internal ref

Page 16

Printed in UKManufacturing Part Number08922-90236

Page 17

31 HP/Agilent 8922 Upgrade KitInstructionsThe HP/Agilent 8922 Upgrade Kit instructions apply to the followingupgrade kits:• HP/Agilent 8922A/B GSM Tes

Page 18

4Purpose of firmware upgrade kitsThe Agilent 8922 firmware upgrade kits allow you to upgrade the HP/Agilent 8922A/B/E/F/G/H/S Operating System firmware t

Page 19

5HP/Agilent 8922A/B Firmware Upgrade Kit,08922-61087, Revision A.05.04Table 1-1 ROM Parts List for Agilent 08922-61087, HP/Agilent 8922A/BFirmware Upg

Page 20 - Completing the ROM upgrade

6HP/Agilent 8922E Firmware Upgrade Kit,08922-61088, Revision A.04.02Table 1-2 ROM Parts List for Agilent 08922-61088, HP/Agilent 8922EFirmware Upgrade

Page 21 - Verifying correct upgrade

7HP/Agilent 8922F Firmware Upgrade Kit,08922-61116, Revision B.06.07Table 1-3 ROM Parts List for Agilent 08922-61116, HP/Agilent 8922FFirmware Upgrade

Page 22

8HP/Agilent 8922G Firmware Upgrade Kit,08922-61089, Revision A.04.02Table 1-4 ROM Parts List for Agilent 08922-61089, HP/Agilent 8922GFirmware Upgrade

Page 23 - 08922-90236

9HP/Agilent 8922H Firmware Upgrade Kit,08922-61117, Revision B.06.07Table 1-5 ROM Parts List for Agilent 08922-61117, HP/Agilent 8922HFirmware Upgrade

Commentaires sur ces manuels

Pas de commentaire