4
Shielding
Front panel EMC gasketing: Front panel gasketing provided per VXI
Rev. 1.4, B.7.2.3
Backplane shielding: Backplane connector shields per VXI
Rev. 1.4, B.7.2.3
Intermodule chassis shielding: Intermodule chassis shields per VXI
Rev. 1.4, B.7.3.4
Airflow
Airflow is routed into the mainframe rear and exhausted
out the left side (viewed from the front with E8408A in
horizontal position). When the mainframe is rack-mounted,
allow 50 mm of clearance at the rear and left side for proper
air flow.
Fan Speed
(Cooling Mode, High or Variable set by front panel switch)
High fan speed mode: Maximum airflow all the time
Variable fan speed mode: Fan speed changes between high and
low as a function of ambient and power
supply temperature.
Agilent E8408A Cooling Specification Chart
VXI-8 Specification Draft 2.0. Fixture revision 1.7.
• VXI-8 Standard Modules installed in all other slots.
• Measurements taken at 1,500 m altitude.
Backplane Specifications
• Solid-state automatic daisy-chain jumpering for
BUS GRANT and IACK signals.
• Full differential distribution of CLK10.
• ACFAIL* and SYSRESET* in full compliance with the
VMEbus and VXIbus Specifications.
• Surface mount construction and no sockets for
maximum reliability.
Mainframe Monitor Specifications
Indicators: (front panel) Power supply output voltages monitor
Power supply temperature monitor
Fan status monitor
Switches: (front panel) On/Standby
Fan Mode: Switches fan between Full
Speed and Variable Speed modes
Environmental
Operating temperature range: 0° C to +55° C
Storage temperature range: –40° C to +70° C
Humidity (non-condensing)
Operating humidity range: Up to 95% RH from
0° C to +40° C,
Up to 65% RH from
+40° C to +55° C
Storage humidity range: Up to 95% RH from
0° C to +55° C,
Up to 90% RH from
+55° C to +65° C
Altitude: Up to 3,000 m
Standards Compliance
100% compatible with the VXIbus Specification Rev 1.4.
Repair
Repair
MTTR = Mean Time to Repair
MTTR, power supply: <20 min. (w/mainframe and modules
fully installed in rack)
MTTR, fan: <30 min. (w/mainframe and modules
fully installed in rack)
General Specifications
MTTR = Mean Time to Repair
VXI device type: Mainframe
Data transfer bus: All per VXIbus Specification, Rev 1.4
Size: C
Slots: 4 available
Connectors: P1/P2
Shared memory: n/a
VXI buses: All per VXIbus Specification, Rev 1.4
VXI Characteristics
Temperature