Computer System and Storage
CPU 300 MHz Microprocessor
Disk Drive 5.5 GByte internal hard drive and 3.5" MS-DOS
®
compatible 120 MB SuperDisk floppy disk drive.
Store and recall setups, waveforms, and screen images to both the hard drive and the floppy
drive. Storage capacity is limited only by disk space.
File Types/Management Setup files .SET
Waveform files .WFM (internal)
Color grade gray scale files .CGS
Waveforms Internal, verbose,Y values
Images bmp, eps , gif, pcx, ps, jpeg, tif
Operating System Microsoft Windows 98
Waveform Store 4 nonvolatile waveform memories
Waveform memory setup (for each channel) (vertical scale, offset, horizontal scale, position)
Printer Configure Printer
Options
Waveform only
Include instrument setup info
Monochrome
Invert waveform background color
Add printer
DISPLAY
Display Area 170.9 mm x 128.2 mm (8.4 inch diagonal color active matrix LCD module incorporating amorphous
silicon TFTs)
Active Display Area 171mm x 128 mm (21,888 square mm) 6.73 in x 5.04 in (33.92 square inches)
Waveform Viewing Area 103 mm x 159 mm (4.06 in x 6.25 in)
Entire Display Resolution 640 pixels horizontally x 480 pixels vertically
Graticule Display Resolution 451 pixels horizontally x 256 pixels vertically
MS-DOS is a U.S. registered trademark of Microsoft Corporation.
8
Mainframe Specifications (continued)
Standard (Direct Trigger) Option 001 (Divided Trigger)
Trigger Modes:
Internal Trigger
1
Freerun
External Direct Trigger
2
Limited Bandwidth
3
DC to 100 MHz
Full Bandwidth DC to 2.75 GHz
External Divided Trigger 2 to 12 GHz (1 to 15 GHz)
Jitter
Characteristic 1.0 ps RMS + 5*10E-5 of delay setting
4
1.2 ps RMS for time delays less than 100 ns
Maximum 1.5 ps RMS + 5*10E-5 of delay setting
4
1.7 ps RMS for time delays less than 100 ns
Sensitivity 200 m Vpp (sinusoidal input or 200 m Vpp sinusoidal input from 2 to 12 GHz
200 ps minimum pulse width)
Trigger Configuration
Trigger Level Adjustment –1 V to + 1 V AC coupled
Edge Select Positive or negative
Hysteresis
5
Normal or high sensitivity
Trigger Gating:
Gating Input Levels Disable: 0 to 0.6 V
(TTL compatible) Enable: 3.5 to 5 V
Pulse width >500 ns, period >1 µs
Gating Delay Disable: 627 ns + trigger period +
Max time displayed
Enable: 100 ns
Trigger Impedance:
Nominal Impedance 50
Reflection 10% for 100 ps rise time
Connector Type 3.5 mm (male)
Maximum Trigger Signal ±2 V + 2 Vac peak (+16 dBm)
1
The freerun trigger mode internally generates an asynchronous trigger that allows viewing the sampled signal amplitude without an external trigger signal but provides no timing information. Freerun is useful in
troubleshooting external trigger problems.
2
The sampled input signal timing is recreated by using an externally supplied trigger signal that is synchronous with the sampled signal input.
3
The DC to 100 MHz mode is used to minimize the effect of high frequency signals or noise on a low frequency trigger signal.
4
Measured at 2.5 GHz with the triggering level adjusted for optimum trigger.
5
High Sensitivity Hysteresis Mode improves the high frequency trigger sensitivity but is not recommended when using noisy, low frequency signals that may result in false triggers without normal hysteresis enabled.