23-5
Measurement Sync Subsystem
SYNC:MODE
SYNC:MODE
Description Selects/queries the SYNC MODE algorithm that is used to determine the location of the
demodulated data bits in the measured burst.
Syntax MSYNc:SYNC:MODE?
MSYNc:SYNC:MODE <string>
Options ’MIDAMBLE’ | ’AMPLITUDE’
Where;
MIDAMBLE means sync using the best bit match of the demodulated data bits to the
selected midamble or user-defined sync pattern.
AMPLITUDE means sync by centering the burst in the detected amplitude envelope.