Agilent Technologies E6701A Guide de l'utilisateur Page 157

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 251
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 156
Agilent PXT Wireless Communications Test Set
User’s Guide
147
Figure 3-4: General Call Setup Procedure Complete
Functional Tests and E2E Test
The following tests can be performed after call procedure is completed. Before performing various tests,
settings for uplink and downlink resource allocation must be set. There are 2 uplink allocation modes,
Auto and Fixed MAC Padding. Auto means the PXT sends an uplink allocation when there is a scheduling
request or buffer status report from the UE, as specified in the 3GPP specification. While, in Fixed MAC
Padding mode, the PXT sends the uplink resource allocation continuously without the UE’s request. This
mode is used for full throughput test or uplink signal test.
There is a configuration for max throughput test in the downlink resource allocation setting as well, which
is Subframe #5 Control. To obtain maximum throughput for DTCH data, select MAX Th.
(SystemInformationBlock on subframe #5 affects the DTCH throughput.)
E2E Tests
Functional Tests
Press the Func front-panel key. The following list of functional tests are displayed:
DTCH Test
UE Power Control
Handover
UE Detach
Paging
Custom Message
PDCCH Order
Vue de la page 156