Performance Tests
FM Frequency Response
3-13
FM Frequency Response
This automated test verifies the FM frequency response specifications. The equipment measures the
variations in frequency deviations due to changes in the applied FM rate; dc to 100 kHz. The variations are
expressed relative to a reference signal; 1 kHz rate set at 100 kHz deviation, in dB. Each frequency is tested
with this sequence:
1. A reference signal is measured.
2. The set deviation is measured for each applied rate change.
3. Each deviation measurement is compared to the reference signal deviation.
The comparison is a calculation of the difference in the deviations relative to the reference rate. The relative
value is the FM frequency response.
Recommended Equipment
Agilent 8902A measuring receiver
Agilent 8904A function generator
Equipment Setup
Figure 3-11 FM Frequency Response Setup