Agilent N5161A/62A/81A/82A/83A MXG Signal Generators User’s Guide 307
Multitone and Two–Tone Waveforms (Option 430)
Using Multitone Modulation
Recalling a Multitone Waveform
Using this procedure, you learn how to recall a multitone waveform from the signal generator’s
memory catalog.
If you have not created and stored a multitone waveform, complete the steps in the previous
sections, Creating a Custom Multitone Waveform on page 297 and Storing a Multitone Waveform on
page 306, then preset the signal generator to clear the stored multitone waveform from volatile ARB
memory.
1. Press Mode > Multitone.
2. Press Load/Store.
3. Highlight the desired file (for example, 5TONE).
4. Press Load From Selected File > Confirm Load From File.
5. Press Multitone Off On until On is highlighted.
The firmware generates the multitone waveform in ARB memory. After waveform generation, the
multitone waveform is available to be modulated on the RF output.
For instruction on configuring the RF output, see Configuring the RF Output on page 306.