144 Agilent E6474A User’s Guide
B Connection Panels and LED Indicators
Trimble Placer GPS 455DR
Figure 110 Trimble Placer connector panel
Tabl e 4 Trimble Placer connector panel descriptions (see Figure 110)
Connector Name Cable Part Number Opposite End of Cable Connects To
GPS Antenna E6450-80002 GPS antenna
Radio 8120-8650 GPS RS-232 port of the E645xx receiver
or
Serial port of the computer (this option requires a Dual Serial Port
PCMCIA card)
MDT/RTCM If you have a Differential GPS, connect its data cable to this port.
This port is also used for sensor calibration. When calibrating,
remove the cable from the Radio port, then connect it to the
MDT/RTCM port. When calibration is complete, reconnect the
cable to the Radio port.
Heading Sensor Trimble p/n 30513 Heading Sensor lead: Connect to the heading sensor
ODO 0 Red lead: Connect to the odometer pulse signal
ODO 0 Black lead: Connect to ground.
Digital I/O (none) (not used)
Power 5182-1290 4-to-1 lighter socket adapter