Agilent Technologies N5416A Manuel de service Page 146

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 236
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 145
146 Notes on USB Electrical Compliance Testing
5 Host Hi-Speed Electrical Tests
3 Click OK to close the Test Instructions dialog.
Test Instructions, Part 2
The USB automated test application will prompt you to perform these
steps:
1 Connect the [TEST PORT] of the E2649- 66402 Host Hi- Speed Signal
Quality test fixture (E2645- 66508 if you are using the old fixture) into
the port under test of the host controller, using the 4" USB cable. The
host controller here refers to the Hi- speed Electrical Test Bed Computer
that has the HS Electrical Test Tool on it.
2 Select TEST_PACKET from the Port Control drop down menu.
3 Enter the port number of the port under test and click [EXECUTE].
This forces the port under test to continuously transmit test packets.
You should see the transmitted test packet on the oscilloscope as below.
Vue de la page 145
1 2 ... 141 142 143 144 145 146 147 148 149 150 151 ... 235 236