Agilent Technologies InfiniiVision 5000 Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Mesure, test et contrôle Agilent Technologies InfiniiVision 5000 Series. Agilent InfiniiVision 5000 Series Portable Oscilloscopes Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 23
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Agilent InfiniiVision 5000
Series Portable Oscilloscopes
Data Sheet
The Next Generation of Portable Oscilloscopes
Vue de la page 0
1 2 3 4 5 6 ... 22 23

Résumé du contenu

Page 1 - Series Portable Oscilloscopes

Agilent InfiniiVision 5000 Series Portable OscilloscopesData SheetThe Next Generation of Portable Oscilloscopes

Page 2

ProbingTogetthemostoutofyourscope,youneed the right probes and accessories foryourapplication.That’swhyAgilentTechnologies offers a com

Page 3 - Don’t take our word for it

Selection guide (continued)Current probes Description 1147B 50-MHz115Acurrentprobe,AC/DC1146A 100-kHzcurrentprobe,AC/DCN2780A 2-MHz/500

Page 4 - Why does deep memory matter?

ConnectivityOurcustomerstellusthatoscilloscopeconnectivityisanincreasinglyimportantfeatureoftheirtestinstruments.That’swhythe5000S

Page 5 - Time Base

Performance characteristicsAcquisitionSamplerate DSO501xA/503xA:2GSa/aeachchannel   DSO505xA:4GSa/shalfchannel1, 2 GSa/s each channelEqui

Page 6 - Software options

Performance characteristics (continued)Vertical system (continued)Range1 2mV/divto5V/div(1MΩor50Ω)Maximuminput Maximuminputvoltagefor

Page 7 - Software options (continued)

Performance characteristics (continued)HorizontalRange DSO501xA:5nsec/divto50sec/div   DSO503xA:2nsec/divto50sec/div   DSO505xA:1nse

Page 8 - Other nice features

Performance characteristics (continued)Trigger system (continued)Selections Edge,pulsewidth,pattern,TV,duration  Edge Triggeronarising,

Page 9

Performance characteristics (continued)Channel triggeringRange(internal) ±6divfromcenterscreenSensitivity1 <10mV/div:greaterof1divo

Page 10 - Selection guide

Performance characteristics (continued)Measurement featuresAutomaticmeasurements Measurementsarecontinuouslyupdated.Cursorstracklastselected

Page 11 - Probing (continued)

Performance characteristics (continued)General characteristicsPhysicalsize 35.4cmwidex18.8cmhighx17.4cmdeep(withouthandle)   38.5cm

Page 12 - Connectivity

2• 100, 300, and 500 MHz bandwidths• 2 or 4 channels• MegaZoom III memory and display technology• 8Mptsacquisitionmemory• Upto100,000wavef

Page 13 - Performance characteristics

Ordering informationAvailable modelsProduct number Description DSO5012A 100MHz,2-channelportableoscilloscopeDSO5014A 100MHz,4-channelportab

Page 14 - (continued)

OptionsProduct number Description SEC Secureenvironmentmode–ProvidescompliancewithNationalIndustrialSecurity   ProgramOperatingManua

Page 15

22Agilent Technologies OscilloscopesMultiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications

Page 16

MicrosoftisaU.S.registeredtrademarkofMicrosoft Corporation.www.lxistandard.orgLANeXtensionsforInstrumentsputsthepowerofEthernetandthe

Page 17

3If you haven’t purchased an Agilent oscilloscope lately, why should you consider one now?Leading-edge technology for all scope usersThe InfiniiVision

Page 18

4Why does deep memory matter?See more timeSeeing more time is the most easily understooduseofdeepmemory.Themoresamplesyouacquire,themoreti

Page 19

5Why does a fast update rate matter?Ifthehumaneyehastroublediscerningabove30-50framespersecond, is there really a difference between 3,600

Page 20 - Ordering information

6Software optionsFigure 7. Real-time totalize functions provide CAN bus efficiency and quality measurement statisticsCAN/LIN triggering and decode (N5

Page 21

7RS-232/UART serial decode and trigger (N5457A or Option 232 on new scope purchases)Theapplicationletsyoueasilyviewtheinformationsentovera

Page 22

8Other nice featuresHigh resolution mode Offersupto12bitsofverticalresolutioninreal-time,single-shotmode. This is accomplished by serially

Page 23 - ISO 9001:2008

9Figure 15. View and analyze previously acquired scope data on a PC-based offline toolOther nice features (continued)Peak detect 250 ps peak detect on

Commentaires sur ces manuels

Pas de commentaire