Agilent Infiniium 90000 A-Series Oscilloscopes at a Glance
Ease of use with high performance
The Agilent Infiniium 90000 A-Series
oscilloscopes combine unprecedented ease-of-
use with high-performance digitizing
oscilloscope functionality to simplify your design
and analysis measurement tasks.
Traditional oscilloscope front-panel
interface provides direct access to the
controls needed for most troubleshooting
tasks.
Graphical user interface with menus,
windows, dialogs, and toolbars provides
easy access to dozens of configuration and
analysis tools, ensuring you can set up and
make the most complex measurements.
All models offer 40 GSa/s sampling rate on all
four channels.
Models with bandwidths from 2.5 GHz to
13 GHz.
Display shows waveforms and graphical
user interface
Graphical interface allows direct interaction
with waveforms, including drag-and-drop
positioning and instant waveform zoom.
Touchscreen display allows oscilloscope
operation without an external pointing
device.
Waveforms displayed in color, making
correlation easy.
Current configuration parameters displayed
near the waveform display and are color-
coded to make identification easy.
Graphical interface menus and toolbars
simplify complex measurement setups.
Horizontal controls set sweep speed and
position
Main sweep speeds from 5 ps/div to 20 s/div.
Zoom mode is from 1 ps/div to main time base
setting.
Intensified waveforms on main sweep
window make it easy to see what will appear
in the zoom window.
Acquisition and general controls start and stop
the scope and do basic setup
Run and stop controls for continuous or single
acquisitions.
Clear display before one or more
acquisitions.
Default setup and Autoscale set initial
configuration.
Hard disk drive and USB 2.0 port for saving and
restoring setups and measurement results
Store measurement displays for inclusion in
reports and test setup guides.
Store oscilloscope setups to repeat tests
another time.
Hard disk stores oscilloscope operating
system.
Trigger setup controls set mode and basic
parameters
Select Edge, Glitch, or Advanced Modes.
Choose input source and slope.
Use graphical user interface to simplify
configuration of pattern, state, delay, and
violation trigger modes.
Use auxiliary trigger to increase triggering
flexibility.
Vertical controls set attenuation, and
position
Input attenuation adjustable from 1 mV/div to
1 V/div.
Color-coded knobs make it easy to find the
controls that affect each waveform.
Marker and quick measurements help
measure waveform parameters
Waveform markers A and B to check voltage
or Δ-time at any point on the displayed
waveform.