676 Appendix D
Softkey Functions
Calibration Menu
(Continued)
Calibrate
4-Port TRL Cal
*2
Reflect Displays softkeys for executing reflection calibrations.
Port 1 Reflect Executes a OPEN/SHORT reflection calibration on test port 1.
:SENS{1-16}:CORR:COLL:TRLR 1
Port 2 Reflect
Executes a OPEN/SHORT reflection calibration on test port 2.
:SENS{1-16}:CORR:COLL:TRLR 2
Port 3 Reflect
Executes a OPEN/SHORT reflection calibration on test port 3.
:SENS{1-16}:CORR:COLL:TRLR 3
Port 4 Reflect
Executes a OPEN/SHORT reflection calibration on test port 4.
:SENS{1-16}:CORR:COLL:TRLR 4
Return
Returns to the softkey display screen one level higher.
Line/Match Displays softkeys for executing LINE/MATCH calibrations.
1-2
Line/Match
Executes a LINE/MATCH calibration on test ports 12.
:SENS{1-16}:CORR:COLL:TRLL 1,2
:SENS{1-16}:CORR:COLL:TRLL 2,1
1-2 Fwd(S21)
Executes a forward LINE/MATCH calibration on test ports 1 and 2.
:SENS{1-16}:CORR:COLL:TRLL 2,1
1-2 Rvs(S12)
Executes a reverse LILNE/MATCH calibration on test ports 1 and
2.
:SENS{1-16}:CORR:COLL:TRLL 1,2
1-3
Line/Match
Executes a LINE/MATCH calibration on test ports 13.
:SENS{1-16}:CORR:COLL:TRLL 1,3
:SENS{1-16}:CORR:COLL:TRLL 3,1
1-3 Fwd(S31)
Executes a forward LINE/MATCH calibration on test ports 1 and 3.
:SENS{1-16}:CORR:COLL:TRLL 3,1
1-3 Rvs(S13)
Executes a reverse LILNE/MATCH calibration on test ports 1 and
3.
:SENS{1-16}:CORR:COLL:TRLL 1,3
1-4
Line/Match
Executes a LINE/MATCH calibration on test ports 14.
:SENS{1-16}:CORR:COLL:TRLL 1,4
:SENS{1-16}:CORR:COLL:TRLL 4,1
1-4 Fwd(S41)
Executes a forward LINE/MATCH calibration on test ports 1 and 4.
:SENS{1-16}:CORR:COLL:TRLL 4,1
1-4 Rvs(S14)
Executes a reverse LINE/MATCH calibration on test ports 1 and 4.
:SENS{1-16}:CORR:COLL:TRLL 1,4
2-3
Line/Match
Executes a LINE/MATCH calibration on test ports 23.
:SENS{1-16}:CORR:COLL:TRLL 2,3
:SENS{1-16}:CORR:COLL:TRLL 3,2
2-3 Fwd(S32)
Executes a forward LINE/MATCH calibration on test ports 2 and 3.
:SENS{1-16}:CORR:COLL:TRLL 3,2
2-3 Rvs(S23)
Executes a reverse LINE/MATCH calibration on test ports 2 and 3.
:SENS{1-16}:CORR:COLL:TRLL 2,3
2-4
Line/Match
Executes a LINE/MATCH calibration on test ports 24.
:SENS{1-16}:CORR:COLL:TRLL 2,4
:SENS{1-16}:CORR:COLL:TRLL 4,2
2-4 Fwd(S42)
Executes a forward LINE/MATCH calibration on test ports 2 and 4.
:SENS{1-16}:CORR:COLL:TRLL 4,2
2-4 Rvs(S24)
Executes a reverse LINE/MATCH calibration on test ports 2 and 4.
:SENS{1-16}:CORR:COLL:TRLL 2,4
3-4
Line/Match
Executes a LINE/MATCH calibration on test ports 34.
:SENS{1-16}:CORR:COLL:TRLL 3,4
:SENS{1-16}:CORR:COLL:TRLL 4,3
3-4 Fwd(S43)
Executes a forward LINE/MATCH calibration on test ports 3 and 4.
:SENS{1-16}:CORR:COLL:TRLL 4,3
3-4 Rvs(S34)
Executes a reverse LINE/MATCH calibration on test ports 3 and 4.
:SENS{1-16}:CORR:COLL:TRLL 3,4
Return
Returns to the softkey display screen one level higher.
Done Terminates a calibration process and calculates the calibration
coefficients.
:SENS{1-16}:CORR:COLL:SAVE
Cancel
Displays softkeys for canceling a calibration.
OK Cancels a calibration process and clears the measurement data of
standard.
:SENS{1-16}:CORR:COLL:CLE
Cancel
Returns to the softkey display screen one level higher.
Return Returns to the softkey display screen one level higher.