Chapter 1: Agilent Technologies 16700A/B-Series Logic Analysis System
Using Both Analyzers
Configure the Timing Analyzer
The Sampling Tab
From the Sampling tab, set the analyzer to Timing Mode, and
configure the Timing Mode Controls as shown below.
The Format Tab
1. Rename the label to Address.
2. Assign the bits that map to the input probe signals.
The Trigger Tab
1. From the Trigger Functions tab, select Find edge AND pattern, then
select Replace.
2. From the Pattern tab, assign Pattern1 the desired pattern you want to
trigger on. In this example we use the pattern "55" Hex. By default, Edge1
is set to don't care which is OK for this example.