Agilent Technologies
54600-Series Oscilloscopes
Data Sheet
Easily see what's happening in your
mixed analog and digital designs!
Unique 2 + 16-channel MSO and
2- or 4-channel models
2 MB of MegaZoom deep memory
per channel
Patented high-definition display
system
Flexible triggering including I
2
C
60- and 100-MHz, 200 MSa/s
Multiple configurations to
meet your needs
If you work with both analog
and digital components,
Agilent-Technologies 54600-Series
oscilloscopes can help you easily
see more of what's going on in your
designs. The unique 2+16-channel
mixed signal oscilloscope (MSO)
models and the traditional 2- and
4-channel models are optimized with
just the capabilities you need for
verifying and debugging designs that
include A/Ds, D/As, DSPs and
embedded 8- or 16-bit microcontrollers.
These scopes give you the tools you
need to solve your mixed analog and
digital engineering challenges more
easily.
What makes these scopes so ideal for
mixed analog and digital analysis?
The 54600-series scopes combine three
critical features:
2 MB of MegaZoom deep memory
on each channel so you can capture
long, non-repeating signals, maintain
high sample rate and quickly zoom in
on areas of interest
a revolutionary ultra-responsive,
high-definition display that's a clearer
"window into your world" – it lets
you see more signal detail than ever
before
flexible triggering that lets you easily
isolate and analyze the complex
signals and fault conditions common
in mixed analog and digital designs.
This combination of capabilities is
tailored to give you the measurement
power you need to get your mixed
analog and digital job done faster.
At Agilent Technologies, we focus
on developing products that help
you do your job better. That's why
54600-Series scopes are optimized for
your needs and why they come in a
variety of configurations. Choose the
one that's right for your application and
your budget.
5968-8152EN.qxd 16/3/00 11:24 am Page 1
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - 54600-Series Oscilloscopes

Agilent Technologies 54600-Series OscilloscopesData SheetEasily see what's happening in your mixed analog and digital designs!• Unique 2 + 16-cha

Page 2 - Selection Guide

ControlsWaveform intensity on front panelVectors on/off; infinite persistenceon/off8 x 10 grid with continuous intensitycontrolBuilt-in Help SystemKey

Page 3

54621A 2-channel 60 MHz Oscilloscope54621D 2+16 channel 60 MHz Mixed Signal Oscilloscope54622A 2-channel 100 MHz Oscilloscope 54622D 2+16 channel 100

Page 4

For more information about AgilentTechnologies test and measurementproducts, applications, services, andfor a current sales office listing, visit our

Page 5

2Model Bandwidth Sample Rate Memory ChannelsHP 54621A 60 MHz 200 MSa/s 2 MB/channel 2HP 54621D 60 MHz 200 MSa/s 2 MB/channel 2+16HP 54622A 100 MHz 200

Page 6 - Probes and Accessories

3The Mixed Signal scopes(models 54621D and 54622D):The 60- and 100-MHz mixed-signaloscilloscopes (MSOs), with 2 analogchannels and 16 digital channels

Page 7

MegaZoom Deep MemoryWith 2 MB of MegaZoom deep memorybehind every channel, 54600-Seriesscopes give you deep-memory capturewithout the sluggish respons

Page 8

Flexible triggeringWith mixed analog and digital designs,sometimes it is hard to trace an anomalyback to its root cause unless you cantrigger on it an

Page 9

6Probes and Accessories10070C 10074C 10076A N2771A(shipped with scope) high-voltage probe high-voltage probeProbe Bandwidth 20 MHz 150 MHz 250 MHz 50

Page 10 - Performance Characteristics

Differential Probe Use the Agilent N2772A differentialprobe with any of the 54600-Seriesoscilloscopes to safely measurefloating circuits with the osci

Page 11 - Ordering Information

Acquisition: Analog ChannelsSample Rate200 MSa/s maximum per scopechannelMemory Depth2 MB/channel 4 MB max with single scopechannel on (Single)Vertic

Page 12

Digital Delta-t Accuracy (non-Vernier settings)Same Channel± 0.01% reading ± 0.1% screenwidth ± (1 digital sample period,2.5 or 5 ns based on sample r