Pulse Switch
The pulse switch includes seven
semiconductor switching relays,
for reliable and direct control of
pulse shaping by the pulse
generator or CPU. The pulse
switch is integrated into the
4073A test head.
Number of Blocks
Two blocks
Number of Switches of Each Block
Block 1:
Three relays (make or break,
selectable type) and 1 relay
(transfer type to create multi-
level pulse)
±60 V between PSI 11 (or PSI 12)
and PSO 1,
between PSI 11 and PSI
12,
between PSI 61 (or PSI 62)
and PSO 6,
between PSI 61 and PSI 62,
between PSI 71 (or PSI 72)
and PSO 7,
between PSI 71 and PSI 72)
Maximum Current
±0.4 A (from input to output)
Residual Resistance (supplemen-
tal characteristics)
Nominal 2 (from IN to OUT)
OFF Capacitance (supplemental
characteristics)
80 pF (between IN and OUT:
Vin–Vout = 0 V)
100 pF (force <-> common @
output of make or break,
selectable type relay: Vin–
Vout = 0 V)
Operating Time of Switching
(supplemental characteristics)
Max. 2 ms
4
Block 2:
One relay (make or break,
selectable type) and two relays
(transfer type to create multi-
level pulse)
Control Input Port
One input per each block (PSC1
and PSC2)
Control Method
Both the PG and CPU can
control all switches. PG or CPU
control is independent for every
block. In the case of PG control,
block 1 can be controlled by the
PSC1 input, and block 2 can be
controlled by either PSC1 or
PSC2 (selectable).
Mode of Relay Control
Make or break, selectable type
relay:
Normally open or Normally
closed modes are selectable.
Transfer type relay:
Normally open and Normally
closed modes are not select-
able.
Pulse Switch
Maximum Voltage
±60 V (between force and com-
mon of each switch)
±60 V (between PSI 21 and PSO
2, between PSI 31 and PSO
3, between PSI 41 and PSO
4, between PSI 51 and PSO
5)
DC Measurement Subsystem: SMU (Source and Monitor Unit)
Voltage Source/Monitor Range, Resolution, and Accuracy using HRSMU
Force Resolution
Measure Resolution:
High Speed
Measure Resolution:
Precision
Force AccuracyMeasure Accuracy
100 µV
1 mV
2 mV
5 mV
100 µV
1 mV
2 mV
5 mV
2 µV
20 µV
40 µV
100 µV
a: 0.02%
b: 0.025%
c: Rmat × Io
a: 0.03%
b: 0.035%
c: Rmat × Io
a: 0.02%
b: 0.015%
c: Rmat × Io
a: 0.03%
b: 0.02%
c: Rmat × Io
Full Scale
Voltage Range
±2 V
±20 V
±40 V
±100 V