various programs for documentation and further anal-
ysis. LAN interface is also available for network file
management and printing.
Powerful Display Modes
Use gray scale and color graded trace displays to gain
insight into device behavior. Waveform densities are
mapped to color or easy-to-interpret gray shades.
These are infinite persistence modes where shading
differentiates the number of times data in any indi-
vidual screen pixel has been acquired.
Internal Triggering Through Clock Recovery
Very high-speed oscilloscopes are not capable of trig-
gering directly on the signal under test. Typically an
external timing reference is used to synchronize the
oscilloscope to the test signal. In cases where a trigger
signal is not available, clock recovery modules are
available to derive a timing reference directly from the
waveform to be measured. The Agilent 8349XA series
of clock recovery modules cover the three most
popular transmission media used today—electrical
lines, multimode, and single-mode fiber. A built-in
coupler reduces external hardware requirements. All
four modules have excellent jitter performance to
ensure accurate measurements. Each clock recovery
module is designed to synchronize to a variety of
common transmission rates.
Improved Autoscaling
Autoscaling has been significantly improved to provide
quick horizontal and vertical scaling of both pulse and
eye-diagram (RZ and NRZ) waveforms.
Time Domain Reflectometer
(TDR)
TDR measurements are focused
on high-speed applications where
it is necessary to optimize elec-
trical system components, such
as microstrip lines, PC board
traces, SMA edge launchers and
coaxial cables where imperfec-
tions cause signal distortion and
reflections. Signal integrity is a
critical requirement in high-
speed digital signal transmission.
Gated Triggering
Trigger gating port allows easy
external control of data acquisi-
tion for circulating loop or burst-data experiments.
Use TTL-compatible signals to control when the
instrument does and does not acquire data.
Easier Calibrations
Calibrating your instrument has been simplified by
placing all the performance level indicators and cali-
bration procedures in a single high-level location. This
provides greater confidence in the measurements
made and saves time in maintaining equipment.
Stimulus Response Testing Using the Agilent
86130A BitAlyzer
®
Error performance analysis represents an essential
part of digital transmission test. The Agilent 86100A
and 86130A BitAlyzer error performance analyzer
share a common interface and together create a
powerful test solution.
Transitioning from the Agilent 83480A
to the 86100A
The 86100A has been designed to be a virtual drop-in
replacement for the Agilent 83480A digital communi-
cations analyzer and Agilent 54750A wide-bandwidth
oscilloscope. All modules used in the Agilent 83480A
and 54750A can also be used in the 86100A. The
remote programming command set for the 86100A has
been designed for direct compatibility with software
written to control the 83480A and 54750A. (Due to
improvements and updates in performance, a small set
of remote commands may need minor modifications to
control the 86100A.) Due to a significantly faster
processor and improved measurement algorithms,
tests run on the 86100A should require less time than
those performed with the
83480A or 54750A.
Modules for the 86100A
Infiniium DCA
The 86100A has a large family of
plug-in modules designed for a
broad range of data rates for
optical and electrical waveforms.
The 86100A can hold up to 2
modules for a total of 4 measure-
ment channels.
The Agilent 86101A module and
86103A has two measurement
channels, one optical and one
electrical. The electrical channel
5