501
Chapter 8, Programming the Call Processing Subsystem
CALL BIT Screen Message Field Descriptions
MS WORD1 Message Fields
Figure 51 MS WORD1 Message Fields
T1T2
This field identifies the received message as an order confirmation, an order, or a called
address message.
2 binary characters required.
DCC
Digital color code field.
2 binary characters required.
MIN1
First part of the mobile identification number field.
24 binary character required.
Parity
Parity field. The contents of the Parity field cannot be set by the user. The Test Set
calculates the parity bits.