Agilent 54753A and 54754ATDR Plug-in ModulesProgrammer’s Quick Reference
Calibrate CommandsCommand :CALibrate:SAMPlers[?] {DISable | ENABle}Enables or disables the samplers in the plug-in.8
Channel CommandsCommand :CHANnel<number>:OFFSet[?] <offset_value>For TDR and TDT applications, you may change the offset to magnify offset
Command :CHANnel<number>:TDRSkew <percent> [%]This command sets the TDR skew for the given channel. The TDR skewcontrol moves the TDR step
Disk CommandsCommand :DISK:LOAD "<filename>", <source>Loads a setup, waveform, database, mask, TDR/TDT calibration, or pixelmemo
Display CommandsCommand :DISPlay:ASSign[?] {CHANnel<number> |FUNCtion<number> | RESPonse<number> |WMEMory<number> | FFT},{UPPe
Function CommandsCommand :FUNCtion{1 | 2}:ADD <source>[,<source>]Defines a function that takes the algebraic sum of two defined operands.&
Command :FUNCtion{1 | 2}:DIFFerentiate {CHANnel<number> |FUNCtion<number> | RESPonse<number> |WMEMory<number> | <float_valu
Command :FUNCtion{1 | 2}:INTegrate {CHANnel<number> |FUNCtion<number> | RESPonse<number> |WMEMory<number> | <float_value>
<number>For channels: an integer, 1 through 4, indicating the slot in which the channelresides, followed by an optional A or B identifying which
Command :FUNCtion{1 | 2}:MULTiply <source>[,<source>]Defines a function that algebraically multiplies the first operand by thesecond opera
iiNotices© Agilent Technologies, Inc. 2000-2004No part of this manual may be repro-duced in any form or by any means (including electronic storage and
Command :FUNCtion{1 | 2}:VERSus <source>[,<source>]Defines a function for an X-versus-Y display. The first operand defines theY axis and t
Histogram CommandsCommand :HISTogram:WINDow:SOURce[?] {CHANnel<number> |FUNCtion<number> | RESPonse<number> |WMEMory<number> |
Limit Test CommandsCommand :LTESt:SWAVeform[?]<source>,<destination>,[,<filename>[,<format>]]Saves waveforms from a channel, f
Marker CommandsCommand :MARKer:MODE[?] {OFF | MANual | WAVeform |MEASurement | HISTogram | TDRTDT}Sets the marker mode.Command :MARKer:PROPagation[?]
Command :MARKer:X1Y1source[?] {CHANnel<number> |FUNCtion<number> | RESPonse<number> |WMEMory<number> | HISTogram | FFT}Sets th
Mask Test CommandsCommand :MTESt:AMASk:SOURce[?] {CHANnel<number> |FUNCtion<number> | RESPonse<number> |WMEMory<number> | FFT}
<number>For channels: an integer, 1 through 4, indicating the slot in which the channelresides, followed by an optional A or B identifying which
Measure CommandsCommand :MEASure:DELTatime[?] [<source>[,<source>]]Measures the delta time between two edges. If one source is specified,
Command :MEASure:FALLtime[?] [<source>]Measures the time at the upper threshold of the falling edge, measures thetime at the lower threshold of
Command :MEASure:NWIDTh[?] [<source>]Measures the width of the first negative pulse on the screen using themid-threshold levels of the waveform
iiiIntroductionIntroduction54750A/83480A MainframesFor controlling 54753A and 54754A TDR plug-in modules that are installed in a 54750A or 83480A main
<number>For channels: an integer, 1 through 4, indicating the slot in which the channelresides, followed by an optional A or B identifying which
Command :MEASure:RISetime[?] [<source>]Measures the rise time of the first displayed edge by measuring the time atthe lower threshold of the ris
Command :MEASURE:TEDge[?] <meas_thres_txt>,<slope><occurrence>[,<source>]Measures the time interval between the trigger event
Command :MEASure:TMIN[?] [<source>]Measures the time at which the first minimum voltage of the sourcewaveform occurred. When FFT is the specifie
Command :MEASure:VAMPlitude[?] [<source>]Calculates the difference between the top and base voltage of the specifiedsource.<source>{CHANne
Command :MEASure:VLOWer[?] [<source>]Measures the voltage value at the lower threshold of the waveform.<source>{CHANnel<number> | FU
Command :MEASure:VMIN[?] [<source>]Measures the absolute minimum voltage present on the selected sourcewaveform. When FFT is the specified sourc
Command :MEASure:VRMS[?] {CYCLe | DISPlay}, {AC | DC}[,<source>]Measures the RMS voltage of the selected waveform by subtracting theaverage valu
Command :MEASure:VTOP[?] [<source>]Measures the statistical top of the selected source waveform.<source>{CHANnel<number> | FUNCtion&
TDR CommandsCommand :TDR{2 | 4}:RESPonse{1 | 2 | 3 | 4}:CALibrateBegins a TDR or TDT normalization and reference plane calibration. Whichcalibration i
ivIntroduction[ ] Square brackets indicate that the enclosed items are optional.{ } When several items are enclosed by braces, one, and only one of th
Command :TDR{2 | 4}:RATE[?] {AUTO | <rate>}Sets the period of the TDR pulse generator. You should usually leave this setto AUTO unless you need
Command :TDR{2 | 4}:RESPonse{1 | 2 | 3 | 4}:RISetime[?]<risetime>Sets the risetime for the normalized response. The risetime setting is limitedb
Command :TDR{2 | 4}:RESPonse{1 | 2 | 3 | 4}:VERTical[?]{TSOurce | MANual}Specifies whether the TDR/TDT response should track the source channel’sverti
Waveform CommandsCommand :WAVeform:SOURce[?] {CHANnel<number> |FUNCtion<number> | RESPonse<number> |WMEMory<number> | DATabase
Waveform Memory CommandsCommand :WMEMory<number>:SAVE {CHANnel<number> |FUNCtion<number> | RESPonse<number> |WMEMory<number
ContentsRoot Level Commands 4Acquire Commands 7Calibrate Commands 8Channel Commands 9Disk Commands 11Display Commands 12Function Commands 13His
Root Level CommandsCommand :BLANk {CHANnel<number> | WMEMory<number> |FUNCtion <number> | FFT | RESPonse<number> |HISTogram |
Command :DIGitize [<waveform_name>][,<waveform_name>]Invokes a special mode of data acquisition that is more efficient than usingthe RUN c
Command :STORe:WAVEform {CHANnel<number> |FUNCtion<number> | WMEMory<number> | HISTogram |FFT | RESPonse<number>},{WMEMory<
Acquire CommandsCommand :ACQuire:BEST[?] {THRuput | FLATness}When averaging is enabled with ACQuire:AVERage, the FLATness optionimproves the step flat