44 Chapter 3
Programming Command Reference
CONFigure Subsystem
This command sets a value of Power Control Level (PWR CNTL) to each of the
High, Medium, and Low ranges for AUTOMATIC TEST, or sets a value of PWR
CNTL for MANUAL TEST, for each radio standard set by the Radio Format
command. The allowable range and preset values are as follows:
Radio Standard
CONFigure:CONDition:RFORmat
GSM900|E-GSM|DCS1800|PCS1900
CONFigure:CONDition:RFORmat?
This command defines a system of Radio Standard to be tested. The choices are
GSM900, E-GSM, DCS1800, and PCS1900. At preset, this is set to GSM900.
RF Output
CONFigure:CONDition:RFOUtput AUTO|ON
CONFigure:CONDition:RFOUtput?
This command defines a mode of RF Output. The choices are AUTO and ON. If
set to AUTO, the RF signal is supplied only during test cycles. At preset, this is set
to ON.
RX Level Limit
CONFigure:CONDition:LIMit:LEVel <int l>,<int h>
CONFigure:CONDition:LIMit:LEVel?
This command specifies the low and high limits for RX Level tests, for each radio
standard set by the Radio Format command. The choices and the preset values are
as follows:
RFORmat Allowable Range
Preset Value
AUTO MANUAL
GSM900 2 (+39 dBm) to 19 (+5 dBm) 5, 10, 15 5
E-GSM 2 (+39 dBm) to 19 (+5 dBm) 5, 10, 15 5
DCS1800 0 (+30 dBm) to 15 (+0 dBm), or
29 (+36 dBm) to 31 (+32 dBm)
0, 5, 10 0
PCS1900 0 (+30 dBm) to 15 (+0 dBm), or
30 (+33 dBm) to 31 (+32 dBm)
0, 5, 10 0