Chapter 3 83
Programming Command Reference
TESTs Subsystem for AUTOMATIC TEST
3. Programming Command
Reference
bit 1 (2): 1st Call
bit 2 (4): Talk
bit 3 (8): RF Test
bit 4 (16): 1st Release
bit 5 (32): 2nd Call
bit 6 (64): 2nd Release
bit 7 (128): Measurement end with test result
bit 8 (256): Measurement end without test result (Aborted or Time out error
occurred)
Talk Test Result
TESTs:AUTO:MEASure:TALK PASS|FAIL
This command verifies whether the test result of the Talk step passes or fails. The
choices are PASS and FAIL. There is no query form of this command.
Talk Test TCH
TESTs:AUTO:TCH <int>
TESTs:AUTO:TCH?
This command specifies the channel number of Traffic Channel for Talk tests, for
each radio standard set by the Radio Format command. The allowable range and
preset values are as follows:
RFORmat Allowable Range Preset Value
GSM900 1 to 124 1
E-GSM 0 to 124, 975 to 1023 1
DCS1800 512 to 885 512
PCS1900 512 to 810 512