Chapter 3 89
Programming Command Reference
TESTs Subsystem for MANUAL TEST
3. Programming Command
Reference
NOTE For Test Sets with Option 002, if the mode is set to ASYNC, this
command is invalid.
For Test Sets with Option 040, if the mode is set to GPRS, this
command is invalid.
MS Release
TESTs:MANual:MEASure:MSRelease
This command executes a release from the mobile. There is no query form of this
command.
NOTE For Test Sets with Option 002, if the mode is set to ASYNC, this
command is invalid.
For Test Sets with Option 040, if the mode is set to GPRS, this
command is invalid.
MS Signal
TESTs:MANual:MEASure:SIGNal BURST|CW
TESTs:MANual:MEASure:SIGNal?
For Test Sets with Option 002, this command defines a signaling type from the
mobile when in the asynchronous mode. The choices are BURST and CW. At
preset, this is set to BURST.
NOTE For Test Sets without Option 002, this is fixed to Burst.
Power Control Level
TESTs:MANual:MEASure:PLEVel <int>
TESTs:MANual:MEASure:PLEVel?
This command specifies a value of Power Control Level for each radio standard set
by the Radio Format command. The allowable range and preset values are as
follows:
RFORmat Allowable Range Preset Value
GSM900 2 (+39 dBm) to 19 (+5 dBm) 5 (+33 dBm)
E-GSM 2 (+39 dBm) to 19 (+5 dBm) 5 (+33 dBm)
DCS1800 0 (+30 dBm) to 15 (+0 dBm), or
29 (+36 dBm) to 31 (+32 dBm)
0 (+30 dBm)
PCS1900 0 (+30 dBm) to 15 (+0 dBm), or
30 (+33 dBm) to 31 (+32 dBm)
0 (+30 dBm)