Local Terminal Configuration
Using the Main Menu
37
2. Select Interface Type and then type Serial.
3. Press 1, Port and then type the Serial Port Number. You see the
current serial port settings (Figure 2-9).
Modify/View Interface Values Menu - Firmware Rev
Interface Type Serial
[1]Port 1.2 Serial
[2]Port Type NA
[3]Serial port IP address 0.0.0.0
[4]Serial port subnet mask 255.255.252.192
[5]Serial port speed 9600
[6]Serial port mode Direct
[7]Serial port hardware flow control On
[8]Modem Init String ^s^M^d1^sATE0Q0V1X4
S0=1...
[9]Modem Hangup String ^d2^s+++^d2^sATH0^M^d2
[10]Modem Connect Responses /CONNECT/300/CONNECT/1200/
...
[11]Modem No-Connect Responses /NO CARRIER/BUSY/NO
DIALT...
S.Save changes and exit
0.Cancel changes and exit
Figure 2-9: Modify/View Serial Port Settings Menu