Exiting the Main Menu and Restarting the Probe
1. On the Main menu, Press
7
to execute a warm start or press
8
to execute a
cold start.
A cold start is required if you change the IP Address, Default Gateway, or
Subnet Mask. For either menu choice, the probe exits the Main Menu and
restarts normal operations.
2. If you are performing the initial probe configuration, prepare the probe for
installation by disconnecting the power cord. You will not lose your initial
configuration information.
NOTE
A warm start resets all data collected by the probe. A cold start resets all data
collected by the probe and also resets any user-configuration information, such as
history studies, filters, and alarms to their default values. Refer to “Probe
Operation” on page 89 for more information on what is reset by warm and cold
starts.
After the probe restarts (boots), it operates normally using the new configuration
information. The warm start or cold start occurs immediately and there is no
visual indication of when it finishes.