Agilent Technologies DisplayPort Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Logiciel Agilent Technologies DisplayPort. Agilent Technologies DisplayPort Technical data Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 152
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - Compliance Testing Notes

Agilent TechnologiessAgilent U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing Notes

Page 2

10 U7232A DisplayPort Compliance Testing Notes

Page 3

100 U7232A DisplayPort Compliance Testing Notes10 Source Inter-Pair Skew Tests

Page 4 - • 1168A or 1169A Probes

Agilent Technologies101 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing Notes11Source Rise And Fall Time Misma

Page 5 - In This Book

102 U7232A DisplayPort Compliance Testing Notes11 Source Rise And Fall Time Mismatch Tests Probing for Single-ended TestsWhen performing the transitio

Page 6 - See Also

Source Rise And Fall Time Mismatch Tests 11U7232A DisplayPort Compliance Testing Notes 103 Figure 38 and Figure 39 below show the single- ended and di

Page 7 - Contents

104 U7232A DisplayPort Compliance Testing Notes11 Source Rise And Fall Time Mismatch Tests .You can use any of the oscilloscope channel and connect th

Page 8

Source Rise And Fall Time Mismatch Tests 11U7232A DisplayPort Compliance Testing Notes 105 Source Rise And Fall Time Mismatch TestsThe rise and fall t

Page 9

106 U7232A DisplayPort Compliance Testing Notes11 Source Rise And Fall Time Mismatch Tests Navigate to the Rise- Fall Mismatch group, and check the Ri

Page 10

Source Rise And Fall Time Mismatch Tests 11U7232A DisplayPort Compliance Testing Notes 107 Table 12 Test Configuration OptionsConfiguration Option De

Page 11 - Application

108 U7232A DisplayPort Compliance Testing Notes11 Source Rise And Fall Time Mismatch Tests Mask Scaling Option Sets the type of scaling performed on t

Page 12 - Installing the Software

Source Rise And Fall Time Mismatch Tests 11U7232A DisplayPort Compliance Testing Notes 109 PASS ConditionFalling Mismatch ≤ 15% of the single- ended r

Page 13 - Installing the License Key

11 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing NotesAgilent Technologiess1Installing the DisplayPort Elect

Page 14

110 U7232A DisplayPort Compliance Testing Notes11 Source Rise And Fall Time Mismatch Tests

Page 15

111 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing NotesAgilent Technologiess12Source Intra-Pair Skew TestsPr

Page 16 - W2641A Test Fixture

112 U7232A DisplayPort Compliance Testing Notes12 Source Intra-Pair Skew Tests Probing for Single-Ended TestsWhen performing the intra- pair skew test

Page 17 - Calibrating the Oscilloscope

Source Intra-Pair Skew Tests 12U7232A DisplayPort Compliance Testing Notes 113 .Infiniium Oscilloscope1168A or 1169A Probe AmplifierN5380A SMA probe h

Page 18

114 U7232A DisplayPort Compliance Testing Notes12 Source Intra-Pair Skew Tests .You can use any of the oscilloscope channel and connect them to any of

Page 19

Source Intra-Pair Skew Tests 12U7232A DisplayPort Compliance Testing Notes 115 Intra-Pair Skew TestThe intra- pair skew test evaluates the skew, or ti

Page 20 - Online Help Topics

116 U7232A DisplayPort Compliance Testing Notes12 Source Intra-Pair Skew Tests Navigate to the Intra- Pair Skew group, and check the lane you want to

Page 21 - Source Eye Diagram Testing

Source Intra-Pair Skew Tests 12U7232A DisplayPort Compliance Testing Notes 117 Table 13 Test Configuration OptionsConfiguration Option DescriptionClo

Page 22 - 3 Source Eye Diagram Testing

118 U7232A DisplayPort Compliance Testing Notes12 Source Intra-Pair Skew Tests Mask Scaling Option Sets the type of scaling performed on the mask for

Page 23

Source Intra-Pair Skew Tests 12U7232A DisplayPort Compliance Testing Notes 119 PASS ConditionIntra- pair Skew ≤ 30 psTest R ef er en ce sSee Test 3.5:

Page 24

12 U7232A DisplayPort Compliance Testing Notes1 Installing the DisplayPort Electrical Performance Compliance Test Application Installing the Software1

Page 25 - Source Eye Diagram Test

120 U7232A DisplayPort Compliance Testing Notes12 Source Intra-Pair Skew Tests

Page 26

121 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing NotesAgilent Technologiess13Source AC Common Mode Noise Te

Page 27

122 U7232A DisplayPort Compliance Testing Notes13 Source AC Common Mode Noise Tests Probing for AC Common Mode Noise TestsWhen performing the AC commo

Page 28

Source AC Common Mode Noise Tests 13U7232A DisplayPort Compliance Testing Notes 123 Figure 46 shows a physical connection for making single- ended con

Page 29

124 U7232A DisplayPort Compliance Testing Notes13 Source AC Common Mode Noise Tests AC Common Mode Noise TestThe AC common mode noise measurement of t

Page 30

Source AC Common Mode Noise Tests 13U7232A DisplayPort Compliance Testing Notes 125 Navigate to the AC Common Mode group, and check the rise time and

Page 31 - Source Total Jitter Tests

126 U7232A DisplayPort Compliance Testing Notes13 Source AC Common Mode Noise Tests Table 14 Test Configuration OptionsConfiguration Option Descripti

Page 32 - Probing for Total Jitter Test

Source AC Common Mode Noise Tests 13U7232A DisplayPort Compliance Testing Notes 127 FFT Acquisition Sets the number of acquisitions used for FFT calcu

Page 33

128 U7232A DisplayPort Compliance Testing Notes13 Source AC Common Mode Noise Tests PASS ConditionAC Common Mode Noise = Nominal Frequency ±300 ppm.Te

Page 34 - 4 Source Total Jitter Tests

129 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing NotesAgilent Technologiess14Calibrating the Infiniium Osci

Page 35

Installing the DisplayPort Electrical Performance Compliance Test Application 1U7232A DisplayPort Compliance Testing Notes 13 Installing the License K

Page 36

130 U7232A DisplayPort Compliance Testing Notes14 Calibrating the Infiniium Oscilloscope and Probe Required Equipment for CalibrationTo calibrate the

Page 37

Calibrating the Infiniium Oscilloscope and Probe 14U7232A DisplayPort Compliance Testing Notes 131 Internal CalibrationThis will perform an internal d

Page 38

132 U7232A DisplayPort Compliance Testing Notes14 Calibrating the Infiniium Oscilloscope and Probe 3 Referring to Figure 49 below, perform the follow

Page 39

Calibrating the Infiniium Oscilloscope and Probe 14U7232A DisplayPort Compliance Testing Notes 133 Figure 50 Oscilloscope Calibration Window5 Follow t

Page 40

134 U7232A DisplayPort Compliance Testing Notes14 Calibrating the Infiniium Oscilloscope and Probe Figure 51 Time Scale Calibration Dialog boxd Click

Page 41 - Source Non-ISI Jitter Tests

Calibrating the Infiniium Oscilloscope and Probe 14U7232A DisplayPort Compliance Testing Notes 135 Probe Calibration and De-skewBefore performing Disp

Page 42 - 5 Source Non-ISI Jitter Tests

136 U7232A DisplayPort Compliance Testing Notes14 Calibrating the Infiniium Oscilloscope and Probe Figure 53 Channel Dialog Box

Page 43

Calibrating the Infiniium Oscilloscope and Probe 14U7232A DisplayPort Compliance Testing Notes 137 2 Referring to Figure 54 below, perform the follow

Page 44

138 U7232A DisplayPort Compliance Testing Notes14 Calibrating the Infiniium Oscilloscope and Probe 3 Referring to Figure 55 below, perform the follow

Page 45 - Non-ISI Jitter Test

Calibrating the Infiniium Oscilloscope and Probe 14U7232A DisplayPort Compliance Testing Notes 139 c Follow the on- screen instructions.d At the end o

Page 46

14 U7232A DisplayPort Compliance Testing Notes1 Installing the DisplayPort Electrical Performance Compliance Test Application

Page 47

140 U7232A DisplayPort Compliance Testing Notes14 Calibrating the Infiniium Oscilloscope and Probe manual comes together with the E2655A/B De- skew Ki

Page 48

Calibrating the Infiniium Oscilloscope and Probe 14U7232A DisplayPort Compliance Testing Notes 141 the Aux Out of the oscilloscope. Do not connect the

Page 49

142 U7232A DisplayPort Compliance Testing Notes14 Calibrating the Infiniium Oscilloscope and Probe f Click on the Setup>Channel 1 menu to open the

Page 50

Calibrating the Infiniium Oscilloscope and Probe 14U7232A DisplayPort Compliance Testing Notes 143 Figure 60 Channel Dialog Box

Page 51 - Source Transition Time Tests

144 U7232A DisplayPort Compliance Testing Notes14 Calibrating the Infiniium Oscilloscope and Probe 2 Referring to Figure 61 below, perform the follow

Page 52

Calibrating the Infiniium Oscilloscope and Probe 14U7232A DisplayPort Compliance Testing Notes 145 c Follow the on- screen instructions.d At the end o

Page 53

146 U7232A DisplayPort Compliance Testing Notes14 Calibrating the Infiniium Oscilloscope and Probe manual comes together with the E2655A/B De- skew Ki

Page 54

147 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing NotesAgilent Technologiess15InfiniiMax ProbingAgilent reco

Page 55

148 U7232A DisplayPort Compliance Testing Notes15 InfiniiMax Probing Table 15 Probe Head CharacteristicsProbe Head Model NumberDifferential Measuremen

Page 56

U7232A DisplayPort Compliance Testing Notes 149 IndexAAC common mode noise tests, 121BBNC to SMA male adapter, 3, 130Ccalibrating the oscilloscope,

Page 57

15 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing NotesAgilent Technologiess2Preparing to Take MeasurementsW2

Page 58

150 U7232A DisplayPort Compliance Testing NotesIndex

Page 60

 Agilent Technologies, Inc. 2007First edition, July 2007This part is not orderable.U7232-97000www.agilent.com Agilent Technologiess

Page 61 - Verification Testing

16 U7232A DisplayPort Compliance Testing Notes2 Preparing to Take Measurements W2641A Test FixtureThe W2641A test fixture is the Agilent DisplayPort t

Page 62

Preparing to Take Measurements 2U7232A DisplayPort Compliance Testing Notes 17 Calibrating the OscilloscopeIf you haven’t already calibrated the oscil

Page 63

18 U7232A DisplayPort Compliance Testing Notes2 Preparing to Take Measurements Starting the DisplayPort Electrical Performance Compliance Test Applica

Page 64

Preparing to Take Measurements 2U7232A DisplayPort Compliance Testing Notes 19 Figure 3 shows the DisplayPort Electrical Performance Compliance Test

Page 65

Notices© Agilent Technologies, Inc. 2007No part of this manual may be reproduced in any form or by any means (including electronic storage and retriev

Page 66

20 U7232A DisplayPort Compliance Testing Notes2 Preparing to Take Measurements Online Help TopicsFor information on using the DisplayPort Electrical P

Page 67

21 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing NotesAgilent Technologiess3Source Eye Diagram TestingProbin

Page 68

22 U7232A DisplayPort Compliance Testing Notes3 Source Eye Diagram Testing Probing for Differential TestsWhen performing the data eye pattern test, th

Page 69

Source Eye Diagram Testing 3U7232A DisplayPort Compliance Testing Notes 23 .Infiniium Oscilloscope1168A or 1169A Probe AmplifierN5380A SMA probe head.

Page 70

24 U7232A DisplayPort Compliance Testing Notes3 Source Eye Diagram Testing .You can use any of the oscilloscope channel and connect them to any of the

Page 71

Source Eye Diagram Testing 3U7232A DisplayPort Compliance Testing Notes 25 Source Eye Diagram Test The eye diagram test provides a visual evaluation o

Page 72

26 U7232A DisplayPort Compliance Testing Notes3 Source Eye Diagram Testing Navigate to the Eye Diagram - Lane # - Eye Diagram Test where # is the la

Page 73

Source Eye Diagram Testing 3U7232A DisplayPort Compliance Testing Notes 27 Table 1 Test Configuration OptionsConfiguration Option DescriptionClock Re

Page 74

28 U7232A DisplayPort Compliance Testing Notes3 Source Eye Diagram Testing FFT Acquisition Sets the number of acquisitions used for FFT calculations.S

Page 75

Source Eye Diagram Testing 3U7232A DisplayPort Compliance Testing Notes 29 PASS ConditionThe following table and figure define the mask for the eye me

Page 76

1U7232A DisplayPort Compliance Testing Notes 3 DisplayPort Automated Testing—At A GlanceThe Agilent U7232A DisplayPort Electrical Performance Complian

Page 77 - Debug Mode

30 U7232A DisplayPort Compliance Testing Notes3 Source Eye Diagram Testing Table 2 Eye Diagram Mask CoordinatesMask Test: Zero mask failures.Test R ef

Page 78

31 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing NotesAgilent Technologiess4Source Total Jitter TestsProbing

Page 79

32 U7232A DisplayPort Compliance Testing Notes4 Source Total Jitter Tests Probing for Total Jitter TestWhen performing the total jitter test, the Disp

Page 80

Source Total Jitter Tests 4U7232A DisplayPort Compliance Testing Notes 33 Figure 10 and Figure 11 below show the single- ended and differential connec

Page 81

34 U7232A DisplayPort Compliance Testing Notes4 Source Total Jitter Tests .You can use any of the oscilloscope channel and connect them to any of the

Page 82

Source Total Jitter Tests 4U7232A DisplayPort Compliance Testing Notes 35 Total Jitter Differential Test To evaluate the total jitter accompanying the

Page 83

36 U7232A DisplayPort Compliance Testing Notes4 Source Total Jitter Tests Navigate to the Total Jitter - Lane # - where # is the lane number to be t

Page 84

Source Total Jitter Tests 4U7232A DisplayPort Compliance Testing Notes 37 Table 3 Test Configuration OptionsConfiguration Option DescriptionClock Rec

Page 85 - Frequency Accuracy Test

38 U7232A DisplayPort Compliance Testing Notes4 Source Total Jitter Tests Mask Scaling Option Sets the type of scaling performed on the mask for the e

Page 86

Source Total Jitter Tests 4U7232A DisplayPort Compliance Testing Notes 39 PASS ConditionUI is Unit Interval.Test R ef er en ce sSee Test 3.12: Total J

Page 87

4 U7232A DisplayPort Compliance Testing Notes1 • 1168A or 1169A Probes• Test fixture (W2641A). Includes four SMA to SMP cables.• U7232A DisplayPort El

Page 88

40 U7232A DisplayPort Compliance Testing Notes4 Source Total Jitter Tests

Page 89

Agilent Technologies41 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing Notes5Source Non-ISI Jitter TestsProbin

Page 90

42 U7232A DisplayPort Compliance Testing Notes5 Source Non-ISI Jitter Tests Probing for Non-ISI Jitter TestWhen performing the non- ISI jitter test, t

Page 91

Source Non-ISI Jitter Tests 5U7232A DisplayPort Compliance Testing Notes 43 .Infiniium Oscilloscope1168A or 1169A Probe AmplifierN5380A SMA probe head

Page 92

44 U7232A DisplayPort Compliance Testing Notes5 Source Non-ISI Jitter Tests .You can use any of the oscilloscope channel and connect them to any of th

Page 93

Source Non-ISI Jitter Tests 5U7232A DisplayPort Compliance Testing Notes 45 Non-ISI Jitter Test To evaluate the Non- ISI jitter accompanying the data

Page 94

46 U7232A DisplayPort Compliance Testing Notes5 Source Non-ISI Jitter Tests Navigate to the Non- ISI Jitter - Lane # - Non- ISI Jitter Test where #

Page 95 - Inter-Pair Skew Test

Source Non-ISI Jitter Tests 5U7232A DisplayPort Compliance Testing Notes 47 Table 5 Test Configuration OptionsConfiguration Option DescriptionClock R

Page 96

48 U7232A DisplayPort Compliance Testing Notes5 Source Non-ISI Jitter Tests Mask Scaling Option Sets the type of scaling performed on the mask for the

Page 97

Source Non-ISI Jitter Tests 5U7232A DisplayPort Compliance Testing Notes 49 PASS ConditionUI is Unit Interval.Test R ef er en ce sSee Test 3.12: Non-

Page 98

1U7232A DisplayPort Compliance Testing Notes 5 In This BookThis manual describes the tests that are performed by the DisplayPort Electrical Performanc

Page 99

50 U7232A DisplayPort Compliance Testing Notes5 Source Non-ISI Jitter Tests

Page 100 - Source Inter-Pair Skew Tests

Agilent Technologies51 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing Notes6Source Transition Time TestsProbi

Page 101 - Agilent Technologies

52 U7232A DisplayPort Compliance Testing Notes6 Source Transition Time Tests Probing for Transition Time TestsWhen performing the transition time test

Page 102

Source Transition Time Tests 6U7232A DisplayPort Compliance Testing Notes 53 Figure 18 and Figure 19 below show the single- ended and differential con

Page 103

54 U7232A DisplayPort Compliance Testing Notes6 Source Transition Time Tests .You can use any of the oscilloscope channel and connect them to any of t

Page 104

Source Transition Time Tests 6U7232A DisplayPort Compliance Testing Notes 55 Source Transition Time Differential TestsTransition time testing measures

Page 105 - Test P ro ce du re

56 U7232A DisplayPort Compliance Testing Notes6 Source Transition Time Tests Navigate to the Transition Time group, and check the rise time and fall t

Page 106

Source Transition Time Tests 6U7232A DisplayPort Compliance Testing Notes 57 Table 7 Test Configuration OptionsConfiguration Option DescriptionClock

Page 107

58 U7232A DisplayPort Compliance Testing Notes6 Source Transition Time Tests Mask Scaling Option Sets the type of scaling performed on the mask for th

Page 108

Source Transition Time Tests 6U7232A DisplayPort Compliance Testing Notes 59 PASS Condition50 ps ≤ Transition Time ≤ 160 psTest R ef er en ce sSee sec

Page 109 - Test R ef er en ce s

6 U7232A DisplayPort Compliance Testing Notes1 See Also• The DisplayPort Electrical Performance Compliance Test Application’s online help, which descr

Page 110

60 U7232A DisplayPort Compliance Testing Notes6 Source Transition Time Tests

Page 111 - Source Intra-Pair Skew Tests

Agilent Technologies61 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing Notes7Source No Pre-emphasis Level Veri

Page 112

62 U7232A DisplayPort Compliance Testing Notes7 Source No Pre-emphasis Level Verification Testing Probing for No Pre-emphasis Level Verification Testi

Page 113 - DisplayPort Test Fixture)

Source No Pre-emphasis Level Verification Testing 7U7232A DisplayPort Compliance Testing Notes 63 .Infiniium Oscilloscope1168A or 1169A Probe Amplifie

Page 114

64 U7232A DisplayPort Compliance Testing Notes7 Source No Pre-emphasis Level Verification Testing .You can use any of the oscilloscope channel and con

Page 115 - Intra-Pair Skew Test

Source No Pre-emphasis Level Verification Testing 7U7232A DisplayPort Compliance Testing Notes 65 No Pre-emphasis Level Verification Test To evaluate

Page 116

66 U7232A DisplayPort Compliance Testing Notes7 Source No Pre-emphasis Level Verification Testing .8 Follow the DisplayPort Electrical Performance Com

Page 117

Source No Pre-emphasis Level Verification Testing 7U7232A DisplayPort Compliance Testing Notes 67 Table 8 Test Configuration OptionsConfiguration Opt

Page 118

68 U7232A DisplayPort Compliance Testing Notes7 Source No Pre-emphasis Level Verification Testing Mask Scaling Option Sets the type of scaling perform

Page 119

Source No Pre-emphasis Level Verification Testing 7U7232A DisplayPort Compliance Testing Notes 69 PASS ConditionThe peak- to- peak voltage must fall w

Page 120

U7232A DisplayPort Compliance Testing Notes 7 ContentsDisplayPort Automated Testing—At A Glance 3Required Equipment and Software 3In This Bo

Page 121

70 U7232A DisplayPort Compliance Testing Notes7 Source No Pre-emphasis Level Verification Testing

Page 122

Agilent Technologies71 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing Notes8Source Pre-emphasis Level Verific

Page 123

72 U7232A DisplayPort Compliance Testing Notes8 Source Pre-emphasis Level Verification Testing Probing for Pre-emphasis Level Verification TestingWhen

Page 124 - AC Common Mode Noise Test

Source Pre-emphasis Level Verification Testing 8U7232A DisplayPort Compliance Testing Notes 73 .Infiniium Oscilloscope1168A or 1169A Probe AmplifierN5

Page 125

74 U7232A DisplayPort Compliance Testing Notes8 Source Pre-emphasis Level Verification Testing .You can use any of the oscilloscope channel and connec

Page 126

Source Pre-emphasis Level Verification Testing 8U7232A DisplayPort Compliance Testing Notes 75 Pre-emphasis Level Verification Test This test evaluate

Page 127

76 U7232A DisplayPort Compliance Testing Notes8 Source Pre-emphasis Level Verification Testing channels of the oscilloscope. If you are using four con

Page 128

Source Pre-emphasis Level Verification Testing 8U7232A DisplayPort Compliance Testing Notes 77 Options may vary depending on the selected mode: Compli

Page 129

78 U7232A DisplayPort Compliance Testing Notes8 Source Pre-emphasis Level Verification Testing Table 9 Test Configuration OptionsConfiguration Option

Page 130

Source Pre-emphasis Level Verification Testing 8U7232A DisplayPort Compliance Testing Notes 79 Mask Scaling Option Sets the type of scaling performed

Page 131 - Internal Calibration

8 U7232A DisplayPort Compliance Testing Notes 5 Source Non-ISI Jitter TestsProbing for Non-ISI Jitter Test 42Non-ISI Jitter Test 45Test Proc

Page 132

80 U7232A DisplayPort Compliance Testing Notes8 Source Pre-emphasis Level Verification Testing PASS ConditionThe pre- emphasis calculation must fall w

Page 133

Agilent Technologies81 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing Notes9Source Frequency Accuracy TestsPr

Page 134

82 U7232A DisplayPort Compliance Testing Notes9 Source Frequency Accuracy Tests Probing for Frequency Accuracy TestsWhen performing the frequency accu

Page 135 - Probe Calibration and De-skew

Source Frequency Accuracy Tests 9U7232A DisplayPort Compliance Testing Notes 83 .Infiniium Oscilloscope1168A or 1169A Probe AmplifierN5380A SMA probe

Page 136 - Figure 53 Channel Dialog Box

84 U7232A DisplayPort Compliance Testing Notes9 Source Frequency Accuracy Tests .You can use any of the oscilloscope channel and connect them to any o

Page 137 - Figure 54 Probe Setup Window

Source Frequency Accuracy Tests 9U7232A DisplayPort Compliance Testing Notes 85 Frequency Accuracy TestThe frequency accuracy measurement of the distr

Page 138

86 U7232A DisplayPort Compliance Testing Notes9 Source Frequency Accuracy Tests Navigate to the Frequency Accuracy group, and check the lanes that you

Page 139

Source Frequency Accuracy Tests 9U7232A DisplayPort Compliance Testing Notes 87 Table 10 Test Configuration OptionsConfiguration Option DescriptionCl

Page 140

88 U7232A DisplayPort Compliance Testing Notes9 Source Frequency Accuracy Tests Mask Scaling Option Sets the type of scaling performed on the mask for

Page 141

Source Frequency Accuracy Tests 9U7232A DisplayPort Compliance Testing Notes 89 Rise-Fall Mismatch Edge Sets the number of edges measured for the rise

Page 142 - Probe Setup window

U7232A DisplayPort Compliance Testing Notes 9 Inter-Pair Skew Test 95Test Procedure 95PASS Condition 99Test References 9911 Source

Page 143 - Figure 60 Channel Dialog Box

90 U7232A DisplayPort Compliance Testing Notes9 Source Frequency Accuracy Tests PASS ConditionFrequency Accuracy = Nominal Frequency ±300 ppm.Test R e

Page 144

Agilent Technologies91 U7232A DisplayPort Electrical Performance Compliance Test ApplicationCompliance Testing Notes10Source Inter-Pair Skew TestsProb

Page 145

92 U7232A DisplayPort Compliance Testing Notes10 Source Inter-Pair Skew Tests Probing for Inter-Pair Skew Single-ended TestsWhen performing the inter-

Page 146 - Figure 63 De-skew Connection

Source Inter-Pair Skew Tests 10U7232A DisplayPort Compliance Testing Notes 93 .Infiniium Oscilloscope1168A or 1169A Probe AmplifierN5380A SMA probe he

Page 147 - InfiniiMax Probing

94 U7232A DisplayPort Compliance Testing Notes10 Source Inter-Pair Skew Tests .You can use any of the oscilloscope channel and connect them to any of

Page 148 - 15 InfiniiMax Probing

Source Inter-Pair Skew Tests 10U7232A DisplayPort Compliance Testing Notes 95 Inter-Pair Skew TestThe inter- pair skew test evaluates the skew, or tim

Page 149

96 U7232A DisplayPort Compliance Testing Notes10 Source Inter-Pair Skew Tests Navigate to the Inter- pair Skew Test group, and check the rise time and

Page 150

Source Inter-Pair Skew Tests 10U7232A DisplayPort Compliance Testing Notes 97 Table 11 Test Configuration OptionsConfiguration Option DescriptionCloc

Page 151

98 U7232A DisplayPort Compliance Testing Notes10 Source Inter-Pair Skew Tests Mask Scaling Option Sets the type of scaling performed on the mask for t

Page 152

Source Inter-Pair Skew Tests 10U7232A DisplayPort Compliance Testing Notes 99 PASS ConditionInter- Pair Skew ≤ 2 UITest R ef er en ce sSee Test 3.4: I

Commentaires sur ces manuels

Pas de commentaire