Vue de la page 68
Source No Pre-emphasis Level Verification Testing 7
U7232A DisplayPort Compliance Testing Notes 69
PASS Condition
The peak- to- peak voltage must fall within the following ranges for each
output level:
Output level 1 (0.4 V): 0.34 V Result 0.46 V
Output level 2 (0.6 V): 0.51 V Result 0.68 V
Output level 3 (0.8 V): 0.69 V Result 0.92 V
Output level 4 (1.2 V): 1.02 V Result 1.38 V
Test R ef er en ce s
See Test 3-2: No Pre-emphasis Level Verification Testing, in the
DisplayPort- Compliance Test Specification Version 1.
Rise-Fall Mismatch Edge Sets the number of edges measured for the rise-fall mismatch test.
Upper Threshold (Debug
only)
Sets the upper threshold used to make a rise time or fall time
measurement.
Lower Threshold (Debug
only)
Sets the lower threshold used to make a rise time or fall time
measurement.
Intra-pair Skew
Intra-pair Edge Sets the number of edges measured for the intra-pair skew test.
AC Common Mode
AC Common Edge Sets the number of edges measured for the AC common mode test.
Table 8 Test Configuration Options
Configuration Option Description