54 U7232A DisplayPort Compliance Testing Notes
6 Source Transition Time Tests
.
You can use any of the oscilloscope channel and connect them to any of
the lane test points. You select the channels used for test a lane in the Set
Up tab of the DisplayPort Electrical Performance Compliance Test
Application.
The data lanes and channels shown in the previous figures are just
examples. You can choose any desired data lane and channel that you
want.
Infiniium Oscilloscope
Data Channel
SMA to SMP cables
DUT
Lane on the W2641A test fixture
Figure 19 Probing for Single-ended Tests - Transition Time Tests (Four Connections with
W2641A DisplayPort Test Fixture)
Vue de la page 53