13
Instrument and Firmware Upgrades
Upgrades for Agilent 8510A
8510C Upgrade (includes on-site installation by
Agilent Customer Engineer)
• 85103C 8510A to 8510C upgrade (replaces the
top unit on the 8510A)
Option 001 adds rack modification kit (for sys-
tems mounted in an 85043A system rack)
Option 002 adds 8360 series source compatibility
kit for 8517A/B test sets
Option 003 adds 8360 series source compatibility
kit for the 8514/15 test sets
Time domain upgrade
• 85012A time domain (Option 010) upgrade for
8510A (customer installed)
Upgrades for Agilent 8510B
8510C Upgrade (includes on-site installation by
Agilent Customer Engineer)
• 85103D 8510B to 8510C upgrade (replaces the
top unit on the 8510B)
Option 001 adds rack modification kit (for sys-
tems mounted in a 85043A system rack)
Option 002 adds 8360 series source compatibility
kit for 8517A/B test sets
Option 003 adds 8360 series source compatibility
kit for the 8514/15 test sets
Wideband IF detector upgrade (reference to 85108A
for additional hardware requirements)
• 85111A pulsed-RF measurement capability
upgrade for the 8510B
(upgrade adds circuitry to the 8510B and
includes on-site installation by Agilent
Customer Engineer.)
Time domain upgrade
• 85012B time domain (Option 010) upgrade for
8510B (customer installed)
Firmware upgrades for 8510B
• 11575E revision 5.14 upgrade (customer installed)
Only for instruments with Rev 5.0 or higher
currently installed.
Option 010 add time domain (for 8510B with
previously installed Option 010)
• 11575H revision 6.54 upgrade (customer
installed)
Only for instruments with Rev 6.3 or higher
currently installed.
Option 010 add time domain (for 8510B with
previously installed Option 010)
• 11575F revision 6.54 upgrade (customer
installed)
For any revision of 8510B firmware currently
installed.
Option 010 add time domain (for 8510B with
previously installed Option 010)
Upgrades for Agilent 8510C
Wideband IF Detector Upgrade (reference to 85108A
for additional hardware requirements)
• 85111B pulsed-RF measurement capability
upgrade for the 8510C
(upgrade adds circuitry to the 8510C and
includes on-site installation by Agilent Customer
Engineer)
Time domain upgrade
• 85012C time domain (Option 010) upgrade for
8510C (customer installed)
Firmware upgrades for 8510C
• 11575G revision 6.54 upgrade (customer
installed)
Only for instruments with Rev 6.0 or higher
currently installed.
• 11575J revision 7.10 upgrade (customer
installed)
For any revision of 8510C firmware currently
installed.
Option 002 adds 8360 series source
compatibility kit for 8517A/B test sets
Option 003 adds 8360 series source compatibility
kit for the 8514/15 test sets