5
System Components
For flexibility in specifying a solution that meets
your exact needs, a system can be ordered as sepa-
rate line items. A complete system includes the
Agilent 8510C network analyzer, a test set, compat-
ible source, and measurement accessories.
All major system components (network analyzer,
test sets, and sources) include one-year on-site
service.
Analyzer (A required system component)
• 8510C network analyzer
Option 008 pulsed-RF measurement capability
Requires HP 85110A or 85110L S-parameter
test set.
Also, see 85108A or 85108L pulsed-RF network
analyzer system.
Option 010 add time domain capability
Option 908 add rack flange kit
Option 910 add extra operating, programming and
service manual set
Option 913 add rack flange and handles kit
Option 916 add extra operating and programming
manual
Option W31 add two years additional on-site
service
Option 1BN add MIL-STD 45662A calibration
certificate
Option 1BP add MIL-STD 45662A calibration
certificate and test data
Test sets (Choose one)
• 8514B S-parameter test set (45 MHz to 20 GHz)
With rugged 3.5 mm connector test ports
• 8515A S-parameter test set (45 MHz to 26.5 GHz)
With rugged 3.5 mm connector test ports
• 8517B S-parameter test set (45 MHz to 50 GHz)
With rugged 2.4 mm connector test ports
• 85110A pulsed-RF S-parameter test set (2 to 20 GHz)
For use with 8510C Option 008. Includes rugged
3.5 mm connector test ports and four built-in
step attenuators to independently set power
level to all four downconverter channels.
Requires 8360 series synthesized sources for
complete operation (83622B and 83624B).
• 85110L pulsed-RF S-parameter test set (45 MHz to
2 GHz)
For use with 8510C Option 008. Includes rugged
7 mm connector test ports and four built-in step
attenuators to independently set power level to
all four downconverter channels. Requires two
8360 series synthesized sources for complete
operation (83620B-H80, two each).
• 8511A frequency converter (45 MHz to 26.5 GHz)
3.5 mm connector ports
• 8511B frequency converter (45 MHz to 50 GHz)
2.4 mm connector ports
Note: Agilent 8511A/B require external, customer-
furnished couplers, or signal separating devices to
provide complete test set capability. A source with
front panel RF power output may be more suitable
for 8511-based applications.
Test set options
Option Description 8514B 8515A 8517B 85110A 85110L 8511A/B
001 Add IF switching for multiple test set operation X X X X X X
002 Delete step attenuators and bias tees X X X
003 High forward dynamic range configuration X
(degrades reverse transmission dynamic range)
004 High power configuration (moves port 2
attenuator in front of b2 sampler) X
007 High dynamic range configuration (adds buffer amplifiers) X
1BN Add MIL-STD 45662A calibration certificate X X X X
1BP Add MIL-STD 45662A calibration certificate and test data X X X X
908 Add rack flange kit X X X X X
913 Add rack flange and handles kit X X X X X
910 Extra operating and service manual X X X X X