Vue de la page 283
Command Reference
Phase Modulation subsystem ([:SOURce])
Chapter 4270
:PM:INTernal:FREQuency:STEP[:INCRement]
Supported PSG-A Series
[:SOURce]:PM:INTernal:FREQuency:STEP[:INCRement] <num>
[:SOURce]:PM:INTernal:FREQuency:STEP[:INCRement]?
This command sets the step increment for the phase modulation internal frequency.
The variable <num> sets the entered value in units of hertz.
*RST
Ν/Α
Range 0.5–1E6
Key Entry
Incr Set
Remarks The value set by this command is used with the UP and DOWN choices
for the
Φ
M frequency command. Refer to
“:PM[1]|2:INTernal[1]|2:FREQuency” on page 274 for more
information.
The setting enabled by this command is not affected by signal
generator power-on, preset, or *RST.
:PM[1]|2:BANDwidth|BWIDth
Supported PSG-A Series
[:SOURce]:PM[1]|2:BANDwidth|BWIDth NORMal|HIGH
[:SOURce]:PM[1]|2:BANDwidth|BWIDth?
This command toggles between normal phase modulation and high bandwidth phase
modulation mode.
*RST NORM
Key Entry
FM ΦM Normal High BW
Remarks N/A