152 Agilent U7232A DisplayPort Electrical Performance Compliance Test Application
17 Link Layer Protocol Tests
Pre-Emphasis PASS Condition
Link Layer Protocol - Pre- Emphasis Test
For 3.5 dB setting: Resultant3.5dB > 2.0 dB
For 6.0 dB setting: Resultant6.0dB results > Resultant3.5dB + 1.6
For 9.5 dB setting: Resultant9.5dB results > Resultant6.0dB + 1.6
Level PASS Condition
Link Layer Protocol - Level Test
Output Level 1: 340 mV < Voltage Peak- Peak < 460 mV
Output Level 2: 510 mV < Voltage Peak- Peak < 680 mV
Output Level 3: 690 mV < Voltage Peak- Peak < 920 mV
Output Level 4: 1020 mV < Voltage Peak- Peak < 1380 mV
Bit Rate PASS Condition
Link Layer Protocol - Bit Rate Test
0.9 * Nominal Bit Rate < Measured Data Rate < 1.1 * Nominal Bit Rate