Agilent Technologies DisplayPort Manuel de service Page 211

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 246
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 210
Cable Non-ISI Jitter Tests 23
Agilent U7232A DisplayPort Electrical Performance Compliance Test Application 211
The following select file dialog box appears. Select your coefficient file
(*.equ) and click Open. The test will run based on the your user defined
coefficient file
PASS Condition
UI is Unit Interval.
Figure 79 Selecting User Defined File
Table 29 Non-ISI Jitter at Internal and Compliance Points.
Receiver package pin Transmitter Connector (TP2)
High-bit Rate (2.7 Gb/s per lane)
A
p-p
0.339 UI 0.330 UI
Reduced-bit Rate (1.62 Gb/s per lane)
A
p-p
0.465 UI 0.442 UI
Vue de la page 210
1 2 ... 206 207 208 209 210 211 212 213 214 215 216 ... 245 246

Commentaires sur ces manuels

Pas de commentaire