To automatically save test violations
The signals that fail the waveform monitoring test can be saved, then
viewed/measured at a later time. Provisions are provided to save the
violations in trace memory, or print a hardcopy of the data. When trace is
selected, the option of saving only the last violation, or saving all violations
are provided.
1
Setup for waveform monitoring as described previously.
2 Press
± .
3 Press the Mask Test softkey.
4 Press the Test Options softkey.
5 Press the Auto Save softkey to ON. This causes the Save To softkey to appear.
Determine how the test violations are being saved, and proceed as follows:
•
To print test violation data on an externally connected printer, toggle the
Save To softkey until Print is selected.
•
To save test violation data in trace memory, toggle the Save To softkey
until Trace is selected. This causes the Increment softkey to appear.
•
To save only the last test violation waveform in trace memory, toggle the
Increment softkey until Off is selected.
•
To save all test violation waveforms in trace memory, toggle the Increment
softkey until On is selected.
6
Press the Previous Menu softkey.
7 Press the Mask Test softkey until On is selected.
Operating the Measurement/Storage Module
To automatically save test violations
2–40