92 Programmer’s Guide
5 Command Reference
Limit Line Y-axis Value
:CALCulate:LLINe[1]:Y <value>
:CALCulate:LLINe[1]:Y?
Sets the Y-axis value of a limit line. Limit line Y-axis value is set
independently and is not affected by the X-axis units.
*RST: 0 dBm
Example: :CALCulate:LLINe:Y -20dBm
Key access: Shift > Limit> Limit 1 > Limit Line
Limit Line X-axis Value
:CALCulate:LLINe:CONTrol:DOMain FREQuency|TIME
:CALCulate:LLINe:CONTrol:DOMain?
Toggles the limit line X-axis value between frequency and time.
Example: :CALCulate:LLINe:CONTrol:DOMain FREQuency
Key access: Shift > Limit > X Axis Units
Limit State
:CALCulate:LLINe[1]|2:DISPlay OFF|ON|0|1
:CALCulate:LLINe[1]|2:DISPlay?
Toggles the limits state between on and off.
Key access: Shift > Limit > Limit 1> Limit On/Off
Query Current Limits Result
:CALCulate:LLINe[1]|2:FAIL?
This query returns the limits pass/failed result. If the test result fail, this
command will get result 1. If the test result pass the limit, it will get
result 0.
Example: :CALCulate:LLINe:FAIL?