Command Reference 5
Programmer’s Guide 151
Measurement Interval State
:CHSCanner:SWEep:INTerval[:STATe] OFF|ON|0|1
:CHSCanner:SWEep:INTerval [:STATe]?
Use this command to turn on/off measurement interval state.
Example: :CHSCanner:SWEep:INTerval ON
Key access: Meas > Setup > Meas Interval
Measurement Interval Type
:CHSCanner:SWEep:INTerval:TYPE TIME|DISTance
:CHSCanner:SWEep:INTerval:TYPE?
This command toggles the interval type between time and distance. The
distance interval type is only available when the GPS is on.
Example: :CHSCanner:SWEep:INTerval:TYPE DISTance
Key access: Meas > Setup > Interval Type
Measurement Interval Time
:CHSCanner:SWEep:INTerval:TIME <value>
:CHSCanner:SWEep:INTerval:TIME?
Use this command to define the measurement interval time.
Range: 100 ms to 3600 s
Example: :CHSCanner:SWEep:INTerval:TIME 10s
Key access: Meas > Setup > Interval Type
Measurement Interval Distance
:CHSCanner:SWEep:INTerval:DISTance <value>
:CHSCanner:SWEep:INTerval:DISTance?
This command defines the measurement interval distance. It’s only
available when the GPS is on. The unit of this parameter is meter.
Range: 1 to 10000
Example: :CHSCanner:SWEep:INTerval:DISTance 1000
Key access: Meas > Setup > Interval Type