68 Programmer’s Guide
5 Command Reference
Store Peak Table to CSV File
:MMEMory:STORe:PEAK <CSV file_name>
To store the current peak table as a CSV file. The suffix of the file name
must be *.csv.
Example: :MMEMory:STORe:PEAK “C:\ABC.CSV”
Key access: Shift > Peak > More > Peak Table > Export Table to CSV
Create A New Directory
:MMEMory:MDIRectory <“dir_path”>
Use this command to create a new directory to the HSA internal
memory or external USB memory.
Example: :MMEMory:MDIRectory “C:\User”
Key access: Shift > File > Directory > Create Folder
Delete A Directory
:MMEMory:RDIRectory <“dir_path”>
Use this command to delete a directory from the internal memory.
Example: :MMEMory:RDIRectory “C:\USER”
Key access: Shift > File > Directory > Delete Folder
Rename A Directory or File
:MMEMory:REName <oldname>,<newname>
To rename a directory or a file.
Example: :MMEMory:REName “C:\USER”,”C:\USER1”
Key access: Shift > File > Directory > Rename Folder