Using Functions
Testing a Dual Band Mobile with AUTOMATIC TEST
2. Using Functions
Testing a Dual Band Mobile with AUTOMATIC TEST
The next procedure explains a test on a dual band (GSM900 and DCS1800) mobile
phone with the AUTOMATIC TEST mode.
Step 1. Turn the Test Set on and wait for its selftest routine to finish.
Step 2. Refer to “Preparation for Each Test” on page 22 for the procedures required before
starting the test.
Step 3. Press the AUTOMATIC TEST softkey in the initial screen.
Step 4. Press the Screen Simp/Detai softkey to select Detai
(detailed screen).
The AUTOMATIC TEST: Stand-by detailed screen should be displayed as shown
below.
Step 5. Rotate the CURSOR CONTROL knob and see how the circular cursor changes its
position.
At one field, press the CURSOR CONTROL knob, then rotate it. You see that field
changes its values. Press the CURSOR CONTROL knob to enter that value.
Step 6