Logic Analyzer Concepts
The Trigger Sequence
Timing analyzer
When you configure a timing analyzer, the trigger sequence follows the
general outlines given previously. The trigger sequence of the timing
analyzer differs from the state analyzer in the following ways:
There are 10 levels available to build a trigger.
The trigger term is always the last step.
The analyzer cannot use pattern terms h and j.
The timing analyzer has two additional resources, Edge1 and Edge2.
Edge1 and Edge2 recognize occurrences of a glitch, rising edge, falling
edge, either edge, or no edge on a bit or ORed set of bits.
State analyzer
When you configure a state analyzer, the trigger sequence follows the
general outlines given previously. The trigger sequence of the state
analyzer differs from the timing analyzer in the following ways:
There are 12 levels available to build a trigger.
The trigger term is never the last step.
The state analyzer cannot use Edge1 and Edge2.
The state analyzer can use pattern terms h and j.