Specifications
General Information
Specifications (logic analyzer)
The specifications are the performance standards against which the
product is tested. Refer to the Agilent Technologies 1670G Logic
Analyzers Service Guide (available from your Agilent Technologies
Sales Office) for testing procedures.
Maximum state speed 150 MHz
Minimum state clock pulse width
*
3.5 ns
Minimum master to master clock time
*
6.66 ns
Minimum glitch width
*
3.5 ns
Setup/Hold time:
*
Single clock, single edges 3.0/0.0 ns through -0.5/3.5 ns,
adjustable in 500-ps increments
Single clock, multiple edges 3.5/0.0 ns through -0.5/4.0 ns,
adjustable in 500-ps increments
Multiple clocks, multiple edges 4.0/0.0 ns through -0.5/4.5 ns,
adjustable in 500-ps increments
*Specified for an input signal VH = -0.9 V, VL = -1.7 V, slew rate = 1 V/ns,