10 Serial Decode/Lister
298 InfiniiVision Oscilloscopes User’s Guide
10 If the decode line does not appear on the display, press the Decode softkey to turn it
on.
11 If the oscilloscope is stopped, press the [Run/Stop] key to acquire and decode data.
You can use the Zoom horizontal sweep mode for easier navigation of the decoded data.
Interpreting CAN Decode
Frame ID appears in hex digits in yellow. Frames of 11 or 29 bits are automatically
detected.
Remote frame (RMT) appears in green.
NOTE
If the setup does not produce a stable trigger, the CAN signal may be slow enough that
the oscilloscope is AutoTriggering. Press the [Mode/Coupling] key, then press the Mode
softkey to set the trigger mode from Auto to Normal.
Missing
Acknowledge
(red)
CRC
(blue)
Data
(white)
Data Length
Code (blue)
Frame ID
(yellow)
Active Error
Frame (red)
Vue de la page 297