Commands by Subsystem 5
Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide 427
:SAVE:SETup[:STARt]
(see page 798)
Command Syntax
:SAVE:SETup[:STARt] [<file_spec>]
<file_spec> ::= {<internal_loc> | <file_name>}
<internal_loc> ::= 0-9; an integer in NR1 format
<file_name> ::= quoted ASCII string
The :SAVE:SETup[:STARt] command saves an oscilloscope setup.
See Also "Introduction to :SAVE Commands" on page 416
":SAVE:FILename" on page 417
":RECall:SETup[:STARt]" on page 414
NOTE
If a file extension is provided as part of a specified <file_name>, it must be ".scp".