554 Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:TRIGger:I2S:TWIDth
(see page 798)
Command Syntax
:TRIGger:I2S:TWIDth <word_size>
<word_size> ::= 4-32 in NR1 format
The :TRIGger:I2S:TWIDth command sets the width of the transmitted data
word in I2S anywhere from 4 bits to 32 bits.
Query Syntax
:TRIGger:I2S:TWIDth?
The :TRIGger:I2S:TWIDth? query returns the currently set I2S transmitted
data word width.
Return Format
<word_size><NL>
<word_size> ::= 4-32 in NR1 format
See Also "Introduction to :TRIGger Commands" on page 479
":TRIGger:I2S:ALIGnment" on page 540
":TRIGger:I2S:CLOCk:SLOPe" on page 542
":TRIGger:I2S:RWIDth" on page 548
":TRIGger:I2S:WSLow" on page 555