Logic Analyzer Reference
The Analyzer Format Menu
Acquisition modes
The Acquisition mode field identifies the channel width and sampling
speed of the present acquisition mode. There are two timing
acquisition modes. State analyzers only have one acquisition mode.
Full-channel 250 MHz. Data is sampled and stored as often as every
4 ns.
Half-channel 500 MHz. Data is sampled and stored as often as every
2 ns, but only one of the pods in each pod pair is active.
150 MHz State. Data is synchronously sampled and stored.
See Also See page 92 for memory configurations.