Logic Analyzer Reference
The Analyzer Trigger Menu
Timing trigger function library
The following list contains all the functions in the library of timing
trigger functions. They are listed in the same order as they appear
onscreen.
User Mode User level - custom combinations, loops
The User level is a user-definable level. This level offers low-level
configuration and uses one internal sequence level. If the "<" duration
is used, four levels are required.
Basic Functions 1. Find edge
This function becomes true when the designated edge is seen. It uses
one internal sequence level.
2. Find Nth occurrence of an edge
This function becomes true when it finds the designated occurrence of
a designated edge. It uses one internal sequence level.
3. Find pattern present/absent for > duration
This function becomes true when it finds a designated pattern that has
been present or absent for greater than or equal to the set duration. It
uses one internal sequence level.
4. Find pattern present/absent for < duration
This function becomes true when it finds a designated pattern that has
been present or absent for less than the set duration. It uses four or
five internal sequence levels.
5. Find anystate "n" times
This function becomes true when the first state it sees occurs "n"
number of times. It uses one internal sequence level.